HP-UX WBEM Fibre Channel Provider release notes (5900-2518, March 2013)
Table 9 Defects fixed in the HP-UX 11i v2 OS (continued)
DescriptionDefect ID
Defects fixed in B.11.23.1003 release
In the previous release, the command evweb eventviewer -En <logIndex> displays
all dynamic data, such as the location of the Fibre-Channel HBAs, in Summary and Description
fields of the output.
QXCR1001073977
In the current release, the command output displays all dynamic data in a variable array in
HPUXFCDIndicationProvider and HPUXTDIndicationProvider.
In the previous release, zombie threads were created in the SFMProviderModule. A
preventive fix is implemented in the HPUXFCIndicationProviderModule.
QXCR100108386
Table 10 Defects fixed in the HP-UX 11i v3 OS
DescriptionDefect ID
Defects fixed in B.11.31.0909 release
In the previous release, when event subscriptions are created by a non-privileged user, the
HPUXFCIndicationProviderModule runs out of file descriptors and stops functioning.
As a result, events reported by the HPUXFCIndicationProviderModule may be lost.
QXCR1000897995 /
QXCR1000988741
In the current release, this defect is fixed. As a result, events reported by the
HPUXFCIndicationProviderModule are not lost even if event subscriptions are created
by a non-privileged user.
Defects fixed in B.11.31.1004 release
In the previous release, during installation of Fibre-Channel provider, the
/FCP-NIP-RUN/configure file contained RAIDSA provider related message.
In the current release, the /FCP-NIP-RUN/ configure file is modified to display Fibre-Channel
provider related message.
QXCR1000995013
In the previous release, events generated by all I/O indication providers were logged in
Fibre-Channel provider database FCPROVDB, available at:/var/opt/psb/db/pgsql .
QXCR1001013221
In the current release, events generated only by Fibre-Channel indication provider gets logged
in the FCPROVDB database, available at: /var/opt/psb/db/pgsql.
In the previous release, the following fields were not populated with appropriate values from
the indications generated by HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule:
QXCR1001012655 /
QXCR1000996830
• Event Threshold
• Event TimeWindow
• SystemSerialNumber
• SystemFirmwareVersion
• SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule.
In the previous release, after OE install, reboot, or upgrade, the Fibre-Channel indication
module times-out while registering with EMS.
QXCR1001001392
In the current release, this defect is fixed by increasing the time-out value of EMS registration.
In the previous release, system log configuration file for Fibre-Channel provider available at:
/var/opt/fcprovider/conf is termed as PSBLoggerConfig.xml.
In the current release, the log configuration file for Fibre-Channel provider available at: /var/
opt/fcprovider/conf is termed as FCLoggerConfig.xml.
QXCR1000947233
10 HP-UX WBEM Fibre Channel provider release Notes