HP-UX WBEM Fibre Channel Provider release notes (5900-2475, September 2012 web release)
Table 9 Defects fixed in the HP-UX 11i v3 OS (continued)
DescriptionDefect ID
This defect is fixed in the current release. The createtable.sh script is modified to check
the cold install and database accordingly.
Defects fixed in version B.11.31.1203.06.02
Upgrade of provider fails on a machine that has a database with large number of record set
and the system runs out of memory while executing the query to fetch all records. The upgrade
fails with the following errors
QXCR1001188297
ERROR: database "FCPROVDB" already exists
ERROR: Operation : createdb FCPROVDB failed
This issue is fixed in this release.
Defects fixed in version B.11.31.1209.08.01
During multiple system reboot, old provider events get reported for FC provider.QXCR1001198841
This issue is fixed in this release. When the old provider events get reported, the following
warning message appears in the provider log:
WARNING! Started processing old osel log files. Old events may get reported.
You can safely ignore this message.
The FCD event 1 is not getting generated for FCNativeIndicationProvider.QXCR1001208648
This issue is fixed in this release. The FCD event 1 is reported for FCNativeIndicationProvider.
When the FC provider, having large number of records in the database is upgraded, the
provider upgrade fails.
QXCR1001200700
This issue is fixed in this release.
Defects fixed in version B.11.31.1209.10.02
When the first node of the hostname is changed to a name that has more than 8 characters,
the FCProvider fails to report the events.
QXCR1001221295
This issue is fixed in this release. The events get generated even after changing the first node
of system name to more than 8 characters.
The event suppression in HPUXFCNativeIndicationProvider is not getting reset after
the system reboot.
QXCR1001230102
This issue is fixed in this release.
In the previous release, cimprovagt process generated a core during unload of the
HPUXFCIndicationProviderModule.
QXCR1001223185
In the current release, this problem is fixed.
Known problems, workarounds, and limitations
The following known problems are for the current release:
• When FC provider B.11.31.1103.14 or later is installed on legacy Integrity systems,
dm_ql_adapter and dm_fclp_adapter are never launched regardless of the diag mode.
HPUXFCNativeIndicationProvider always monitors natively the hardware and generates WBEM
events. The reverse wrapper, FC_Wbemwrapper, may be launched depending on the
connected hardware. This reverse wrapper converts the WBEM event to the corresponding
EMS event.
The introduction of this native support adds to support the following EMS resource paths:
/adapters/events/ql_wrapper_wbem
/adapters/events/fclp_wrapper_wbem
14 HP-UX WBEM Fibre Channel provider release Notes