HP-UX WBEM Fibre Channel Provider release notes (5900-2475, September 2012 web release)
Table 9 Defects fixed in the HP-UX 11i v3 OS (continued)
DescriptionDefect ID
Table 10 (continued)
Previous severity LevelCurrent severity Level
Subsystem
GroupOperationalStatus
Unknown(0) and No
Contact(12).
• Stopping(9)
• In Service(11)
• Dormant(15)
• Power Mode(18)
Has higher severity level
than the states OK(2)
and Completed(17).
Has less severity level than the
states OK(2) and
Completed(17).
• Unknown(0)
• No Contact(12)
Has the lowest severity
level.
Has the highest severity level.
• OK(2)
• Completed(17)
Defects fixed in B.11.31.1109 release
In the previous release on HP 9000 systems, the test event fields of Fibre-Channel Instance
provider were displaying as unknown and Not Available.
QXCR1001106830
This defect is fixed in the current release. The test event fields are getting displayed correctly.
In the previous release, the HPUXFCIndicationProviderModule data had junk values
at the end in evweb o/p under "Error Details/Component Data".
QXCR1001053727
This defect is fixed in the current release. Void Pointer is passed to the EMS API which fills the
"Error Details/Component Data".
In the previous release, core file generated by cimprovagt, program terminated with signal
11, resulting in segmentation fault.
QXCR1001051369
This defect is fixed in the current release.
Defects fixed in B.11.31.1203 release
When a provider is disabled, the failure messages are logged in syslog. This is because, the
time taken by the provider registration/reply with monitor exceeds the time limit set for the
cimserver shutdown.
QXCR1001030689
This defect is fixed in this release. Timeout is set for each monitor request/reply calls and
provider shutdown failure messages are not seen in syslog.
Some of the FCD and FCLP event fields in /var/opt/resmon/log/event.log from CED
database are displayed as NA.
QXCR1001146566
This defect is fixed in the current release.
The Provider Data Sheets (PDS) is no longer shipped as part of the depot. The latest PDS is
available at http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?
QXCR1001087417
lang=en&cc=us&taskId=101&prodClassId=10008&contentType=SupportManual&
docIndexId=64255&prodTypeId=18964&prodSeriesId=4183083
The system crashes during the FC provider upgradation.QXCR1001163320
This defect is fixed in the current release.
The system crashes while registering and unregistering the provider along with the event
generation in process.
QXCR1001164894
This defect is fixed in the current release.
The install logs present under the /var/opt/ directory displays unwanted messages during
cold install for RAIDSA, SAS, DAS, and FC providers
QXCR1001133148
Defects fixed in this version 13