HP-UX WBEM Fibre Channel Provider release notes (5900-2475, September 2012 web release)

Table 9 Defects fixed in the HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the previous release, enumeration of HP_FCRecordLog class on NGIS displays
DISKPROVDB database name in the Description field. For information about supported
NGIS, see Table 3 (page 6).
QXCR1000995514
In the current release, enumeration of HP_FCRecordLog class on NGIS displays FCPROVDB
database name in the Description field.
In the previous release, on NGIS platform, description of error for FCD event numbers 15 and
49 are set as Not Available.
QXCR1001023565
In the current release, this defect is fixed. Description of error for FCD event numbers 15 and
49 are displayed appropriately.
In the previous release, Fibre-Channel indication provider does not display multiple IP addresses
on all systems.
QXCR1000996827 /
QXCR1001023213
In the current release, Fibre-Channel indication provider displays multiple IP addresses on all
systems.
In the previous release, Fibre-Channel indication and Consolidated Status providers display
erroneous data on HP Virtual Machine guest systems.
QXCR1001022697
In the current release, Fibre-Channel indication and Consolidated Status providers are disabled
on HP Virtual Machine guest systems.
In the previous release, Fibre-Channel provider event details were not formatted correctly on
legacy systems. This defect is fixed in the current release.
QXCR1000993005
On HP-UX system, enumerate instance of HPUX_FCPortControllerCollection class
returns incorrect data when FC port controllers are not present.
QXCR1001029324
In the previous release, memory leak is encountered in the
HPUXFCNativeIndicationProviderModule when the evweb logviewer -L command
is invoked on NGIS platform. This defect is fixed in the current release.
QXCR1001023590
Defects fixed in B.11.31.1103 release
In the previous release, the Fibre-Channel Instance provider does not display correct Speed
and Max Speed values for the following Fibre-Channel adapters:
QXCR1001038978
451871-B21 PCIe 2-port 8Gb QLogic Mezzanine Fibre Channel adapter
AH400A PCIe 1-port 8Gb Qlogic Fibre Channel adapter
AH401A PCIe 2-port 8Gb Qlogic Fibre Channel adapter
456972-B21 PCIe 2-port 8GB Emulex Fibre Channel adapter
In the current release, the SNIA library call is modified to handle the above listed adapters.
The SNIA library call retrieves the Speed and Max Speed values for the adapters and enables
the Fibre-Channel Instance provider to display appropriate values for these fields.
In the previous release, on BL870c i2 platform, the Fibre-Channel adapter test command:QXCR1001058688
#/opt/fcprovider/bin/FC_Provider_test -d
fails to generate events for all subsequent Fibre-Channel adapters available on the system if
the first instance of the adapter is not supported by the
HPUXFCNativeIndicationProviderModule.
This defect is fixed in the current release on BL870c i2 platform. The Fiber-Channel adapter
tests are enhanced to send events for all the monitored paths even if the first instance of the
adapter is not supported by the HPUXFCNativeIndicationProviderModule.
In the previous release on HP-UX 11i v3 OS, enumeration of classes available in Fibre-Channel
Instance provider and Fibre-Channel Consolidated Status provider fails for a user with non-root
privileges.
QXCR1001068706
This defect is fixed in the current release. Enumeration of classes available in Fibre-Channel
Instance provider and Fibre-Channel Consolidated Status provider is successful even for a
normal user.
Defects fixed in this version 11