HP-UX WBEM Fibre Channel Provider release notes (5900-2475, September 2012 web release)

Table 9 Defects fixed in the HP-UX 11i v3 OS
DescriptionDefect ID
Defects fixed in B.11.31.0909 release
In the previous release, when event subscriptions are created by a non-privileged user, the
HPUXFCIndicationProviderModule runs out of file descriptors and stops functioning.
As a result, events reported by the HPUXFCIndicationProviderModule may be lost.
QXCR1000897995 /
QXCR1000988741
In the current release, this defect is fixed. As a result, events reported by the
HPUXFCIndicationProviderModule are not lost even if event subscriptions are created
by a non-privileged user.
Defects fixed in B.11.31.1004 release
In the previous release, during installation of Fibre-Channel provider, the
/FCP-NIP-RUN/configure file contained RAIDSA provider related message.
In the current release, the /FCP-NIP-RUN/ configure file is modified to display Fibre-Channel
provider related message.
QXCR1000995013
In the previous release, events generated by all I/O indication providers were logged in
Fibre-Channel provider database FCPROVDB, available at:/var/opt/psb/db/pgsql .
QXCR1001013221
In the current release, events generated only by Fibre-Channel indication provider gets logged
in the FCPROVDB database, available at: /var/opt/psb/db/pgsql.
In the previous release, the following fields were not populated with appropriate values from
the indications generated by HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule:
QXCR1001012655 /
QXCR1000996830
Event Threshold
Event TimeWindow
SystemSerialNumber
SystemFirmwareVersion
SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule.
In the previous release, after OE install, reboot, or upgrade, the Fibre-Channel indication
module times-out while registering with EMS.
QXCR1001001392
In the current release, this defect is fixed by increasing the time-out value of EMS registration.
In the previous release, system log configuration file for Fibre-Channel provider available at:
/var/opt/fcprovider/conf is termed as PSBLoggerConfig.xml.
In the current release, the log configuration file for Fibre-Channel provider available at: /var/
opt/fcprovider/conf is termed as FCLoggerConfig.xml.
QXCR1000947233
In the previous release, Memory leak encountered due to ComponentData indication
properties of HPUXFCIndicationProviderModule.
QXCR1001016011
In the current release, this defect is fixed.
In the previous release, the moncheck displayed an illegal severity level as "??"QXCR1000965458
This defect is fixed in the current release. The provider registers with the ems Registrar for
events with severity greater than or equal to 1.
Defects fixed in B.11.31.1009 release
In the previous release, Memory leak encountered in cimprovagt/
HPUXFCNativeIndicationProviderModule provider module on NGIS. For information
about supported NGIS, see Table 3 (page 6)
QXCR1001023590
In the current release, this defect is fixed.
10 HP-UX WBEM Fibre Channel provider release Notes