HP-UX WBEM Fibre Channel Provider release notes (5900-1780, September 2011)
Known Problems, Workarounds, Limitations
The following known problems are for the current release:
• When FC Provider B.11.31.1103.14 or later is installed on legacy Integrity systems,
dm_ql_adapter and dm_fclp_adapter are never launched regardless of the diag mode.
HPUXFCNativeIndicationProvider always monitors natively the hardware and generates WBEM
events. The reverse wrapper, FC_Wbemwrapper, may be launched depending on the
connected hardware. This reverse wrapper converts the WBEM event to the corresponding
EMS event.
The introduction of this native support adds to support the following EMS resource paths:
/adapters/events/ql_wrapper_wbem
/adapters/events/fclp_wrapper_wbem
On the other hand, as the process for disk_em and msamon_sas are never launched, the
corresponding EMS resource paths are not monitored:
/adapters/events/ql_adapter
/adapters/events/fclp_adapter
Related Documentation
Table 7 lists the available documentation for the WBEM providers:
Table 11 WBEM Provider Related Documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com
and
Information about HP WBEM Services
http://www.hp.com
http://www.openpegasus.org/uploads/40/3452/WBEMIndications.pdfOverview of the Indication Schema
Datasheets of all the providers are installed along with the product at the following
location on the system:/opt/<provider-name>/doc
Provider Datasheets
The datasheets are also available at the following location:
www.hp.com/go/hpux-networking-docs and select HP-UX 11i WBEM Software
collection.
Localized Version of the Software
The product is supported only in English locale (LANG=C). Behavior of the product is unpredictable
when LANG value is set to any other language code other than C. Documentation support for this
product is also available only in English locale.
Known Problems, Workarounds, Limitations 13