HP-UX WBEM Fibre-Channel Indication Provider Datasheet, April 2010
/var/stm/config/tools/monit
or/wbem_msamon_sas.clcfg
Using This Provider
Schema supported by this
provider
This Provider services HP_DeviceIndication class and is compliant with CIMSchema V2.7. Table 1 shows
the properties of HP_DeviceIndication class that are supported by the provider.
Clients are expected to:
Subscribe to this provider using a CIMClient (could be Java/C++ client or wbemexec)
Write an appropriate WBEM consumer to consume the indications generated by
HPUXFCDIndicationProvider, HPUXTLIndicationProvider and HPUXFCLPIndicationProvider.
Additionally, on HPUX11iv2, HPUXFCIndicationProviderModule monitors the following devices,
Device Names
Provider Names
DS2500 Storage Enclosure
GazeIndicationProvider
MSA 30 and MSA 1000/1500
MsaIndicationProvider
MSA 60 and MSA
70
MsaSASIndicationProvider
RAIDSA Adapters
HPUXRAIDSAIndicationProvider
SAS Adapters
HPUXSASIndicationProvider
Table 1: HP_DeviceIndication and base classes’ supported properties. (Properties that are not supported are not mentioned.)
Table 1 describes the properties of the HP_DeviceIndication and base classes’ . It has three columns. The first is the property name (including type
and units), the second lists the property inheritance (indicating which class or super class defines the property), and the third discusses the property
and its value. Each row describes a property. Note: while some properties in the table are marked with the “Write” qualifier (based on their
designation in the DMTF CIM schema), all properties are in fact read-only for this version of the HP-UX FC Provider.
Property name Property inheritance Property value (and data source
1
)
Properties of CIM_Indication
String
IndicationIdentifier
Inherited from CIM_Indication
A unique identifier for the i
ndication similar to a key
value that can be used for identification.
For example for
HPUXFCNativeIndicationProviderModule,
_eventNumber+ an index ( value ranges from 0-99
recyclically) + CIMDateTime.toString()
For example for HPUXFCIndicationProviderModule,
_eventNumber+ an index (starting from 0) + the current
Operating System Time.
datetime
IndicationTime
Inherited from CIM_Indication
The time and date when the indication was created.
For example, CIMDateTime.getCurrentDateTime()
Properties of CIM_AlertIndication
String
Descrip
tion
Inherited from CIM_AlertIndication
A short description of the i
ndication. This property
corresponds to “Description of Error” field in the event
notification.
String
AlertingManagedElement
Inherited from CIM_AlertIndication
The identifying informat
ion of the entity (ie, the instance)
for which this Indication is generated. The property
contains the path of an instance, encoded as a string
parameter - if the instance is modeled in the CIM
Schema. If
it is
not a CIM instance, the property contains