HP-UX WBEM Fibre Channel (FC) Provider Release Notes (September 2013)

Table 10 Defects fixed in the HP-UX 11i v3 OS (continued)
DescriptionDefect ID
This defect is fixed in this release. Timeout is set for each monitor request/reply calls and
provider shutdown failure messages are not seen in syslog.
Some of the FCD and FCLP event fields in /var/opt/resmon/log/event.log from CED
database are displayed as NA.
QXCR1001146566
This defect is fixed in the current release.
The Provider Data Sheets (PDS) is no longer shipped as part of the depot. The latest PDS is
available at http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?
QXCR1001087417
lang=en&cc=us&taskId=101&prodClassId=10008&contentType=SupportManual&
docIndexId=64255&prodTypeId=18964&prodSeriesId=4183083
The system crashes during the FC provider upgradation.QXCR1001163320
This defect is fixed in the current release.
The system crashes while registering and unregistering the provider along with the event
generation in process.
QXCR1001164894
This defect is fixed in the current release.
The install logs present under the /var/opt/ directory displays unwanted messages during
cold install for RAIDSA, SAS, DAS, and FC providers
QXCR1001133148
This defect is fixed in the current release. The createtable.sh script is modified to check
the cold install and database accordingly.
Defects fixed in version B.11.31.1203.06.02
Upgrade of provider fails on a machine that has a database with large number of record set
and the system runs out of memory while executing the query to fetch all records. The upgrade
fails with the following errors
QXCR1001188297
ERROR: database "FCPROVDB" already exists
ERROR: Operation : createdb FCPROVDB failed
This issue is fixed in this release.
Defects fixed in version B.11.31.1209.08.01
During multiple system reboot, old provider events get reported for FC provider.QXCR1001198841
This issue is fixed in this release. When the old provider events get reported, the following
warning message appears in the provider log:
WARNING! Started processing old osel log files. Old events may get reported.
You can safely ignore this message.
The FCD event 1 is not getting generated for FCNativeIndicationProvider.QXCR1001208648
This issue is fixed in this release. The FCD event 1 is reported for FCNativeIndicationProvider.
When the FC provider, having large number of records in the database is upgraded, the
provider upgrade fails.
QXCR1001200700
This issue is fixed in this release.
Defects fixed in version B.11.31.1209.10.02
When the first node of the hostname is changed to a name that has more than 8 characters,
the FCProvider fails to report the events.
QXCR1001221295
This issue is fixed in this release. The events get generated even after changing the first node
of system name to more than 8 characters.
The event suppression in HPUXFCNativeIndicationProvider is not getting reset after
the system reboot.
QXCR1001230102
This issue is fixed in this release.
Defects fixed in this version 15