HP-UX WBEM Fibre Channel (FC) Provider Release Notes (September 2013)
Table 9 Defects fixed in the HP-UX 11i v2 OS (continued)
DescriptionDefect ID
Defects fixed in B.11.23.1003 release
In the previous release, incorrect hardware path and World Wide Number (WWN) of the
hardware are displayed on System Management Homepage (SMH) for a dual/multi port
Fibre-Channel Card.
In the current release, this defect is fixed. On HP–UX 11i v2 OS, two tables namely FC Ports
and FC Controllers are displayed on the SMH page. The FC Controllers table displays
QXCR1001017067
information about the physical cards on the machine. The FC Ports table displays information
about the individual ports.
Defect fixed in B.11.23.1012 release
In the previous release, the command evweb eventviewer -En <logIndex> displays
all dynamic data, such as the location of the Fibre-Channel HBAs, in Summary and Description
fields of the output.
QXCR1001073977
In the current release, the command output displays all dynamic data in a variable array in
HPUXFCDIndicationProvider and HPUXTDIndicationProvider.
In the previous release, zombie threads were created in the SFMProviderModule. A
preventive fix is implemented in the HPUXFCIndicationProviderModule.
QXCR100108386
Table 10 Defects fixed in the HP-UX 11i v3 OS
DescriptionDefect ID
Defects fixed in B.11.31.0909 release
In the previous release, when event subscriptions are created by a non-privileged user, the
HPUXFCIndicationProviderModule runs out of file descriptors and stops functioning.
As a result, events reported by the HPUXFCIndicationProviderModule may be lost.
QXCR1000897995 /
QXCR1000988741
In the current release, this defect is fixed. As a result, events reported by the
HPUXFCIndicationProviderModule are not lost even if event subscriptions are created
by a non-privileged user.
Defects fixed in B.11.31.1004 release
In the previous release, during installation of Fibre-Channel provider, the
/FCP-NIP-RUN/configure file contained RAIDSA provider related message.
In the current release, the /FCP-NIP-RUN/ configure file is modified to display Fibre-Channel
provider related message.
QXCR1000995013
In the previous release, events generated by all I/O indication providers were logged in
Fibre-Channel provider database FCPROVDB, available at:/var/opt/psb/db/pgsql .
QXCR1001013221
In the current release, events generated only by Fibre-Channel indication provider gets logged
in the FCPROVDB database, available at: /var/opt/psb/db/pgsql.
In the previous release, the following fields were not populated with appropriate values from
the indications generated by HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule:
QXCR1001012655 /
QXCR1000996830
• Event Threshold
• Event TimeWindow
• SystemSerialNumber
• SystemFirmwareVersion
• SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule.
Defects fixed in this version 11