HP-UX WBEM Fibre Channel (FC) Provider Release Notes HP-UX 11i v1, HP-UX 11i v2, HP-UX 11i v3 HP Part Number: 5900-3281 Published: September 2013 Edition: 2
Legal Notices © Copyright 2003, 2013 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents HP secure development lifecycle......................................................................4 1 Fibre Channel (FC) provider release notes for September 2013 release..............5 Announcement.........................................................................................................................5 HP-UX WBEM Fibre Channel provider.........................................................................................5 What's new in this release.............................
HP secure development lifecycle Starting with HP-UX 11i v3 March 2013 update release, HP secure development lifecycle provides the ability to authenticate HP-UX software. Software delivered through this release has been digitally signed using HP's private key. You can now verify the authenticity of the software before installing the products, delivered through this release. To verify software signatures in signed depot, version B.11.31.1303 or later of Software Distributor (SD) and version A.01.01.
1 Fibre Channel (FC) provider release notes for September 2013 release This document discusses the most recent product information on HP-UX WBEM Fibre Channel (FC) provider, which is supported on HP-UX 11i v1, HP-UX 11i v2, and HP-UX 11i v3 operating systems. Table 1 (page 5) lists the product versions for which the document is applicable. Table 1 Documentation Support for Fibre Channel provider Operating system Version HP-UX 11i v3 B.11.31.1309.08.
What's new in this release The FCProvider config and log files are available in the following directories: /var/opt/psb/diags/conf/fcprovider/ /var/opt/psb/diags/log/fcprovider/ For information about defect fixes, see “Defects fixed in this version” (page 10). Installing HP-UX WBEM Fibre Channel provider The WBEM FC provider depot is available for download on the OE media and web.
Table 3 Fibre-Channel provider supported platforms (continued) Provider name Product name Supported platforms • SD16, SD32, SD64 • SD16A, SD32A, SD64A • SD16B, SD32B, SD64B HP Integrity servers • cx2600 • cx2620 • rx1600 • rx1620 • rx2600 • rx2620 • rx2660 • rx3600 • rx4640 • rx5670 • rx6600 • rx7620 • rx7640 • rx8620 • rx8640 • SD16A, SD32A, SD64A • SD16B, SD32B, SD64B • BL60p HP Server Blade • BL860c HP Server Blade • BL870c HP Server Blade • BL860c i2, BL870c i2 & BL890c i2 • rx2800 i2 • Superdome 2 •
Table 4 Fibre-Channel provider software requirement (continued) SysMgmtPlus A.01.00 HP-UX 11i v3 Integrity system and PA-RISC system WBEM Services A.02.05 or later on HP-UX 11i HP-UX 11i v1, HP-UX 11i v2, HP-UX 11i v3 Integrity and v2 system and A.02.09.04 or PA-RISC system later on HP-UX 11i v3 system EMS-Core A.04.00.01 HP-UX 11i v3 PA-RISC system OnlineDiag B.11.31.06.
Table 7 Fibre-Channel adapter list (continued) AB379A PCI-X Dual Port 4Gb Fibre Channel Adapter AB378B PCI-X Single Port 4Gb Fibre Channel Adapter AB379B PCI-X Dual Port 4Gb Fibre Channel Adapter AD193A PCI-X 4Gb Fibre Channel/Gigabit Ethernet (Copper) Combination Adapter AD194A PCI-X 4Gb Fibre Channel/Gigabit Ethernet (Copper) Combination Adapter AD300A PCIe Dual Port 4Gb Fibre Channel Adapter A5158A A6795A AD299A (1-port 4G PCI-e Adapter) AD355A (2-port 4G PCI-e Adapter) 402631-B21 (2-port 4G PCI-e Adapte
Defects fixed in this version This section describes the WBEM Fibre-Channel provider defects fixed in the HP-UX 11i v1, 11i v2, and 11i v3 operating systems. Table 8 Defect fix in the HP-UX 11i v1 OS Defect ID Description Defect fix in B.11.11.08 release QXCR1000954635 During previous release, the FCIndicationProvider process running for a considerable amount of time causes memory leak. In the current release, this defect is fixed and the FCIndicationProvider process does not cause memory leak.
Table 9 Defects fixed in the HP-UX 11i v2 OS (continued) Defect ID Description Defects fixed in B.11.23.1003 release QXCR1001017067 In the previous release, incorrect hardware path and World Wide Number (WWN) of the hardware are displayed on System Management Homepage (SMH) for a dual/multi port Fibre-Channel Card. In the current release, this defect is fixed. On HP–UX 11i v2 OS, two tables namely FC Ports and FC Controllers are displayed on the SMH page.
Table 10 Defects fixed in the HP-UX 11i v3 OS (continued) Defect ID QXCR1001001392 Description In the previous release, after OE install, reboot, or upgrade, the Fibre-Channel indication module times-out while registering with EMS. In the current release, this defect is fixed by increasing the time-out value of EMS registration. QXCR1000947233 In the previous release, system log configuration file for Fibre-Channel provider available at: /var/opt/fcprovider/conf is termed as PSBLoggerConfig.xml.
Table 10 Defects fixed in the HP-UX 11i v3 OS (continued) Defect ID QXCR1001038978 Description In the previous release, the Fibre-Channel Instance provider does not display correct Speed and Max Speed values for the following Fibre-Channel adapters: • 451871-B21 PCIe 2-port 8Gb QLogic Mezzanine Fibre Channel adapter • AH400A PCIe 1-port 8Gb Qlogic Fibre Channel adapter • AH401A PCIe 2-port 8Gb Qlogic Fibre Channel adapter • 456972-B21 PCIe 2-port 8GB Emulex Fibre Channel adapter In the current release, the
Table 10 Defects fixed in the HP-UX 11i v3 OS (continued) Defect ID QXCR1001021582 Description In the previous release, the HPUXFCNativeIndicationProviderModule does not generate events related to HP 580151-B21 10Gb PCIe 2-port OCm10102-F-HP FCoE Mezzanine adapter on BL870c i2 platform. In the current release, the HPUXFCNativeIndicationProviderModule generate all events related to HP 580151-B21 10Gb PCIe 2-port OCm10102-F-HP FCoE Mezzanine adapter on BL870c i2 platform.
Table 10 Defects fixed in the HP-UX 11i v3 OS (continued) Defect ID Description This defect is fixed in this release. Timeout is set for each monitor request/reply calls and provider shutdown failure messages are not seen in syslog. QXCR1001146566 Some of the FCD and FCLP event fields in /var/opt/resmon/log/event.log from CED database are displayed as NA. This defect is fixed in the current release. QXCR1001087417 The Provider Data Sheets (PDS) is no longer shipped as part of the depot.
Table 10 Defects fixed in the HP-UX 11i v3 OS (continued) Defect ID QXCR1001223185 Description In the previous release, cimprovagt process generated a core during unload of the HPUXFCIndicationProviderModule. In the current release, this problem is fixed. Defects fixed in version B.11.31.1303.05.01 QXCR1001232692 During the unconfiguration of FCProvider, the native library gets deleted. Therefore, configuring of FCProvider fails. This issue is fixed in this release.
Workaround: You can select any of the following two alternatives: 1. To install the product on the DRD cloned disk as a normal upgrade scenario. The scenario will be same as fresh installation and user may refer to event.log for historical event data. 2. To have a seamless migration of the data from postgres 7.4.2 version. In this case, the user is required to perform the manual steps listed in the Installation scenarios of Postgres 8.4.8 guide at www.hp.com/go/hpux-diagnostics-sfm-docs.
2 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.