HP-UX WBEM FC (Fibre-Channel) Provider Release Notes (766962-001, March 2014)

Table 19 B.11.31.1009 (continued)
DescriptionDefect ID
On HP-UX system, enumerate instance of HPUX_FCPortControllerCollection class returns
incorrect data when FC port controllers are not present.
QXCR1001029324
In the previous release, memory leak is encountered in the
HPUXFCNativeIndicationProviderModule when the evweb logviewer -L command is
invoked on NGIS platform. This defect is fixed in the current release.
QXCR1001023590
Defect fixes in B.11.31.1004 release
Table 20 B.11.31.1004
DescriptionDefect ID
In the previous release, during installation of FC (Fibre-Channel) provider, the
/FCP-NIP-RUN/configure file contained RAIDSA provider related message.
QXCR1000995013
In the current release, the /FCP-NIP-RUN/ configure file is modified to display FC (Fibre-Channel)
provider related message.
In the previous release, events generated by all I/O indication providers were logged in FC
(Fibre-Channel) provider database FCPROVDB, available at:/var/opt/psb/db/pgsql .
QXCR1001013221
In the current release, events generated only by FC (Fibre-Channel) indication provider gets logged
in the FCPROVDB database, available at: /var/opt/psb/db/pgsql.
In the previous release, the following fields were not populated with appropriate values from the
indications generated by HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule:
QXCR1001012655/
QXCR1000996830
Event Threshold
Event TimeWindow
SystemSerialNumber
SystemFirmwareVersion
SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXFCIndicationProviderModule and HPUXFCNativeIndicationProviderModule.
In the previous release, after OE install, reboot, or upgrade, the FC (Fibre-Channel) indication module
times-out while registering with EMS.
QXCR1001001392
In the current release, this defect is fixed by increasing the time-out value of EMS registration.
In the previous release, system log configuration file for FC (Fibre-Channel) provider available at:
/var/opt/fcprovider/conf is termed as PSBLoggerConfig.xml.
In the current release, the log configuration file for FC (Fibre-Channel) provider available at: /var/
opt/fcprovider/conf is termed as FCLoggerConfig.xml.
QXCR1000947233
In the previous release, Memory leak encountered due to ComponentData indication properties of
HPUXFCIndicationProviderModule.
QXCR1001016011
In the current release, this defect is fixed.
In the previous release, the moncheck displayed an illegal severity level as "??"QXCR1000965458
This defect is fixed in the current release. The provider registers with the ems Registrar for events with
severity greater than or equal to 1.
Defects fixed in various versions 15