HP-UX WBEM FC (Fibre-Channel) Provider Release Notes (766962-001, March 2014)
Table 14 B.11.31.1203 (continued)
DescriptionDefect ID
The Provider Data Sheets (PDS) is no longer shipped as part of the depot. The latest PDS is available
at http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp.
QXCR1001087417
The system crashes during the FCProvider upgradation.QXCR1001163320
This defect is fixed in the current release.
The system crashes while registering and unregistering the provider along with the event generation
in process.
QXCR1001164894
This defect is fixed in the current release.
The install logs present under the /var/opt/ directory displays unwanted messages during cold
install for RAIDSA, SAS, DAS, and FCProviders.
QXCR1001133148
This defect is fixed in the current release. The createtable.sh script is modified to check the cold
install and database accordingly.
Defect fixes in B.11.31.1109 release
Table 15 B.11.31.1109
DescriptionDefect ID
In the previous release on HP 9000 systems, the test event fields of FC (Fibre-Channel) Instance
provider were displaying as unknown and Not Available.
QXCR1001106830
This defect is fixed in the current release. The test event fields are getting displayed correctly.
In the previous release, the HPUXFCIndicationProviderModule data had junk values at the end
in evweb o/p under "Error Details/Component Data".
QXCR1001053727
This defect is fixed in the current release. Void Pointer is passed to the EMS API which fills the "Error
Details/Component Data".
In the previous release, core file generated by cimprovagt, program terminated with signal 11, resulting
in segmentation fault.
QXCR1001051369
This defect is fixed in the current release.
Defect fixes in B.11.31.1103.14 release
Table 16 B.11.31.1103.14
DescriptionDefect ID
In the previous release, the HPUXFCNativeIndicationProviderModule is not supported on
legacy Integrity systems.
QXCR1001048147
In the current release, the HPUXFCNativeIndicationProviderModule is supported on legacy
Integrity systems. The monitors dm_ql_adapter and dm_fclp_adpater no longer generate events
on legacy Integrity systems.
In the previous release, the HPUXFCNativeIndicationProviderModule does not generate
events related to HP 580151-B21 10Gb PCIe 2-port OCm10102-F-HP FCoE Mezzanine
adapter on BL870c i2 platform.
QXCR1001021582
In the current release, the HPUXFCNativeIndicationProviderModule generate all events related
to HP 580151-B21 10Gb PCIe 2-port OCm10102-F-HP FCoE Mezzanine adapter on
BL870c i2 platform.
In the previous release, when the evweb eventviewer command runs on legacy and PA-RISC
platforms, event descriptions of events generated by the HPUXFCIndicationProviderModule
may contain special characters.
QXCR1001092354
12 FC (Fibre-Channel) provider release notes for March 2014 release