HP-UX WBEM Direct Attached Storage (DAS) Provider Release Notes (September 2013)

Due to the missing data compatibility between PostgreSQL version 7.4.2 (prior to September
2012) and 8.4.8 (September 2012 release or later) when diagnostics products are upgraded
from prior to September 2012 release to September 2012 web release and later, the postgres
data need to be migrated to 8.4.8 format. Data migration involves backup in 7.4.2 version
using the pg_dumpall and restore in 8.4.8 version using the psql operations. Both of these
operations requires a running postgres service. But in the DRD environment there is a limitation
that no service can be run on the cloned disk when products are either installed or upgraded.
This limits diagnostics product upgrade steps from taking the backup of the postgres 7.4.2
data. As a result, the data such as events and error records is lost during such circumstances.
Workaround: You can select any of the following two alternatives:
1. To install the product on the DRD cloned disk as a normal upgrade scenario. The scenario
will be same as fresh installation and user may refer to event.log for historical event data.
2. To have a seamless migration of the data from postgres 7.4.2 version. In this case, the
user is required to perform the manual steps listed in the Installation scenarios of Postgres
8.4.8 guide at www.hp.com/go/hpux-diagnostics-sfm-docs.
The product has the following limitation:
It is a read-only provider and hence does not allow users to modify, create, or delete instances.
For disks having capacity more than 2TB (terrabyte), the “Capacity” field in the disk instance
output contains value as “Not Available.
Related documentation
Table 10 lists the available documentation for the WBEM providers:
Table 10 WBEM provider Related Documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com
and
Information about HP WBEM Services
http://www.hp.com
http://www.openpegasus.org/uploads/40/3452/WBEMIndications.pdfOverview of the indication schema
The datasheets are available at the following location:Provider Datasheets
http://www.hp.com/go/hpux-networking-docs
Localized version of the software
The product is supported only in English locale (LANG=C). Behavior of the product is random and
variable, when LANG value is set to any other language code other than C. Documentation support
for this product is also available only in English locale.
18 Direct Attached Storage (DAS) provider release notes for September 2013 release