HP-UX WBEM Direct Attached Storage (DAS) Provider Release Notes (September 2013)
Table 8 Defects fixed in HP-UX 11i v3 OS (continued)
The following error message is logged in DASProvider log:QXCR1001228957
SFM: ERROR: invalid input syntax for type timestamp with time zone: ""
This issue is fixed in this release.
The DASProvider is generating core during provider initialization/event generation.QXCR1001235345
This issue is fixed in this release.
Known problems, workaround, and limitations
Following is the known problem tabulated from the current release.
Problem: After the installation of DAS Provider, couple of initial events are not generated.
Workaround: After installation run /opt/dasprovider/bin/Disk_Provider_test -a
twice.
The following known problems are tabulated from the previous release.
• After updating a system from HP-UX 11i Base OE B.11.31.1009 (September 2010) to HP-UX
11i Base OE B.11.31.1103 (March 2011) using update-ux(1M), the
WBEMP-Storage.STORAGE-PROV-RUN fileset is not configured. Trying to configure the fileset
using swconfig (1M) also fails.
The following is seen in the /var/adm/sw/swagent.log file:
* Running "configure" script for fileset "WBEMP-Storage.STORAGE-PROV-RUN".
NOTE: Disabling old Disk Native Provider.
ERROR:
PGC00617: Disabling the provider module...
PGS00414: Connection timed out.
NOTE: Removing old Disk Native Provider.
NOTE:
PGC00614: Deleting the provider module...
PGC00607: The provider is deleted successfully.
NOTE: Creating the Disk log database
NOTE: Disk log database setup completed.
NOTE: Registering Storage WBEM Indication Provider schema
NOTE: Registering Storage WBEM Instance Provider schema
NOTE: Registering Storage WBEM Record Log Provider
NOTE: Registering Storage Native Control Provider
NOTE: Registering the Storage WBEM Native Provider.
ERROR: The "configure" script for "WBEMP-Storage.STORAGE-PROV-RUN" failed (exit code "1"). The script
location was “/var/adm/sw/products/WBEMP-Storage.2/STORAGE-PROV-RUN/configure”.
Workaround: Uninstall the currently running DASProvider (where the problem is seen) and
install either DAS provider version B.11.31.1106 or B.11.31.1109.05.01.
• When DAS provider B.11.31.1103.15 or later is installed on legacy Integrity systems, disk_em
and msamon_sas are not launched regardless of the diag mode.
HPUXDiskNativeIndicationProvider always natively monitors the hardware and generates
WBEM events. The reverse wrapper, DAS_WbemWrapperMonitor, and/or
MSA_WbemWrapperMonitor may be launched depending on the connected hardware. These
reverse wrappers convert the WBEM event to the corresponding EMS event.
The introduction of this native support adds to support the following EMS resource paths:
/storage/events/DAS_wrapper_wbem
/storage/events/MSA_wrapper_wbem
On the other hand, as the process for disk_em and msamon_sas are not launched, the
corresponding EMS resource paths are not monitored:
/storage/events/disks/default
/storage/events/enclosures/msamon_sas
• Problem: The events are lost when diagnostic products are upgraded on a DRD cloned disk.
Description: Prior to September 2012 release version of diagnostics product, the postgres
7.4.2 version was supported. However version 8.4.8 is shipped from September 2012 release.
Known problems, workaround, and limitations 17