HP-UX WBEM DAS Provider Release Notes, August 2010
In the previous release, events generated by all I/O Indication providers were logged
in DAS provider database DISKPROVDB, available at the location:/opt/psb/db/
pgsql/bin/psql
In the current release, events generated only by DAS Indication provider gets logged
in the DISKPROVDB database, available at the location: /opt/psb/db/pgsql/bin/
psql.
QXCR1001013221
In the previous release, following fields were not populated with appropriate values
from the indications generated by HPUXStorageIndicationProviderModule
and HPUXStorageNativeIndicationProviderModule:
• Event Threshold
• Event TimeWindow
• SystemSerialNumber
• SystemFirmwareVersion
• SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXStorageIndicationProviderModule and
HPUXStorageNativeIndicationProviderModule.
QXCR1001012655 /
QXCR1000996830
In the previous release, after OE install, reboot, or upgrade, the DAS Indication
module times-out while registering with EMS.
In the current release, this defect is fixed by increasing the time-out value of EMS
registration.
QXCR1001001392
In the previous release, system log configuration file for DAS provider available at:
/var/opt/storageprovider/conf is termed as PSBLoggerConfig.xml.
In the current release, the log configuration file for DAS Provider available at: /var/
opt/storageprovider/conf is termed as DASLoggerConfig.xml.
QXCR1000947233
In the previous release, Memory leak encountered due to ComponentData Indication
properties of HPUXStorageIndicationProviderModule.
In the current release, this defect is fixed.
QXCR1001016011
Defects Fixed in version B.11.31.1009
In the previous release, the HPUXStorageNativeProviderModule dumps core
when directly attached disk, which is not supported by HP disk firmware, is removed
from HP Superdome 2 platform. This defect is fixed in the current release.
QXCR1001008709
In the previous release, when the evweb logviewer command is run on the new
Integrity platform, the Sense code and Information field values of the Native
Indication provider are displayed in integer format. These values must be displayed
in Hexadecimal format.
In the current release, the Sense code and Information field values of the
Native Indication provider are displayed in Hexadecimal format when the evweb
logviewer command is run on all the platforms.
QXCR1000992649
In the previous release, DAS provider event details were not formatted correctly on
legacy systems. This defect is fixed in the current release.
QXCR1000993005
While installing the WBEMP-Storage module, version B.11.31.0903 on HP-UX system,
a temporary file /diskaldata is created and does not get deleted after successful
installation.
In the current version of the product, the temporary file gets deleted after successful
installation of the module.
QXCR1000996182
In the previous release, DAS Indication and Consolidated Status provider displays
erroneous data on HP Virtual Machine guest systems.
In the current release, DAS Indication and Consolidated Status providers are disabled
on HP Virtual Machine guest systems.
QXCR1001022697
Defects Fixed in This Version 13