HP-UX WBEM DAS Provider release notes (5900-2516, March 2013)
Table 8 Defects fixed in HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the current release, events generated only by DAS indication provider gets logged
in the DISKPROVDB database, available at the location: /opt/psb/db/pgsql/
bin/psql.
In the previous release, following fields were not populated with appropriate values
from the indications generated by HPUXStorageIndicationProviderModule
and HPUXStorageNativeIndicationProviderModule:
QXCR1001012655 / QXCR1000996830
• Event Threshold
• Event TimeWindow
• SystemSerialNumber
• SystemFirmwareVersion
• SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXStorageIndicationProviderModule and
HPUXStorageNativeIndicationProviderModule.
In the previous release, after OE install, reboot, or upgrade, the DAS indication
module times-out while registering with EMS.
QXCR1001001392
In the current release, this defect is fixed by increasing the time-out value of EMS
registration.
In the previous release, system log configuration file for DAS provider available at:
/var/opt/storageprovider/conf is termed as PSBLoggerConfig.xml.
In the current release, the log configuration file for DAS provider available at:
/var/opt/storageprovider/conf is termed as DASLoggerConfig.xml.
QXCR1000947233
In the previous release, Memory leak encountered due to ComponentData indication
properties of HPUXStorageIndicationProviderModule.
QXCR1001016011
In the current release, this defect is fixed.
In the previous release, the moncheck displayed an illegal severity level as "??"QXCR1000965458
This defect is fixed in the current release. The provider registers with the ems Registrar
for events with severity greater than or equal to 1.
Defects fixed in version B.11.31.1009
In the previous release, the HPUXStorageNativeProviderModule dumps core
when directly attached disk, which is not supported by HP disk firmware, is removed
from HP Superdome 2 platform. This defect is fixed in the current release.
QXCR1001008709
In the previous release, when the evweb logviewer command is run on the new
Integrity platform, the Sense code and Information field values of the
QXCR1000992649
Native indication provider are displayed in integer format. These values must be
displayed in Hexadecimal format.
In the current release, the Sense code and Information field values of the
Native indication provider are displayed in Hexadecimal format when the evweb
logviewer command is run on all the platforms.
In the previous release, DAS provider event details were not formatted correctly on
legacy systems. This defect is fixed in the current release.
QXCR1000993005
While installing the WBEMP-Storage module, version B.11.31.0903 on HP-UX
system, a temporary file /diskaldata is created and does not get deleted after
successful installation.
QXCR1000996182
In the current version of the product, the temporary file gets deleted after successful
installation of the module.
Defects fixed in this version 9