HP-UX WBEM DAS Provider release notes (5900-2516, March 2013)

Table 8 Defects fixed in HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the current release, event numbers 7 and 8 are no longer supported by the
HPUXStorageNativeIndicationProviderModule on legacy Integrity and
BL870c i2 platforms. For information about the events, see http://
bizsupport1.austin.hp.com/bizsupport/TechSupport/SupportTaskIndex.jsp?lang=en&
cc=us&taskId=110&prodTypeId=18964&prodSeriesId=4183083
In the previous release, on legacy integrity and BL870c i2 platforms, when
excessive errors are generated from a faulty component, the DISKPROVDB database
QXCR1001083290
connection with the HPUXStorageNativeIndicationProviderModule exceeds
the threshold limit. This potentially leads to core dump.
In the current release, the defect is fixed and excessive errors generated from a
faulty component are handled appropriately.
In the previous release, the HPUXStorageNativeIndicationProviderModule
is not supported on legacy Integrity systems.
QXCR1001048147
In the current release, the HPUXStorageNativeIndicationProviderModule
is supported on legacy Integrity systems. The monitors disk_em and msamon_sas
no longer generate events on legacy Integrity systems.
The consolidated status provider displays the overall status of the IO subsystem
based on the GroupOperationalStatus property severity level. The severity
QXCR1001066416
levels associated for the GroupOperationalStatus property values during the
previous release and the current release are tabulated below.
Table 9
Earlier Severity LevelCurrent Severity Level
Subsystem
GroupOperationalStatus
Has higher severity
level than the states
Has less severity level than the
states Unknown(0) and No
Contact(12).
Other(1)
Starting(8)
Unknown(0) and No
Contact(12).
Stopping(9)
In Service(11)
Dormant(15)
Power Mode(18)
Has higher severity
level than the states
Has less severity level than the
states OK(2) and
Completed(17).
Unknown(0)
No Contact(12)
OK(2) and
Completed(17).
Has the lowest
severity level.
Has the highest severity level.
OK(2)
Completed(17)
In the previous release, the HPUXStorageNativeIndicationProviderModule
does not support event 15 on legacy Integrity and BL870c i2 platforms.
QXCR1001097747
In the current release, the HPUXStorageNativeIndicationProviderModule
supports event 15 on legacy Integrity and BL870c i2 platforms.
In the previous release, the HPUXStorageNativeIndicationProviderModule
supports a constant polling interval of 20 minutes on legacy Integrity and BL870c
i2 platforms.
QXCR1001095319
In the current release, a new poller configuration file included in the
HPUXStorageNativeIndicationProviderModule allow customers to set the
polling interval on legacy Integrity and BL870c i2 platforms.
In the previous release, enumeration of the HP_DiskDrive class does not return
the component data as required.
QXCR1001091192
12 HP-UX WBEM Direct Attached Storage provider release notes