HP-UX WBEM DAS Provider release notes (5900-2516, March 2013)
Table 8 Defects fixed in HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the previous release, DAS indication and Consolidated Status provider displays
erroneous data on HP Virtual Machine guest systems.
QXCR1001022697
In the current release, DAS indication and Consolidated Status providers are disabled
on HP Virtual Machine guest systems.
In the previous release, the Disk exerciser tool (shipped in the product bundle) does
not work after bundle installation or upgrade. The cimserver or the
CDM-ProvidersModule has to be restarted to make the Disk exerciser tool work.
QXCR1001023857
In the current release, this defect is fixed and the Disk exerciser tool works correctly
after the bundle installation or upgradation.
In the previous release, DAS indication provider does not display multiple IP
addresses supported for a system.
QXCR1000996827 / QXCR1001023213
In the current release, DAS indication provider displays multiple IP addresses
supported for a system.
In the previous release, on HP-UX system, enumerate instance of HPUX
HP_DiskDrive class returns incorrect data when DAS port controllers are not
present on new Integrity servers.
QXCR1001029288
In the current release, this defect is fixed.
Defects fixed in version B.11.31.1103
In the previous release on BL870c i2 platform, the evweb logviewer command
displays incorrect or incomplete event details for secondary storage devices. As a
result, users will be unable to locate faulty device attached to the system.
QXCR1001042481
This defect is fixed in the current release. A new field Hardware Path is added
in the evweb logviewer output. This field provides complete hardware path of
the failing hardware.
In the previous release on BL870c i2 platform, the
HPUXStorageNativeIndicationProviderModule fails to generate
esdisk/escsi related events on the platform.
QXCR1001042893
In the current release, this defect is fixed and the
HPUXStorageNativeIndicationProviderModule generate esdisk/escsi
related events on BL870c i2 platform.
In the previous release, the VirtualSystemSerialNo and SystemSerialNo
fields display incorrect value when the command evweb logviewer is run on
BL870c i2 platform.
QXCR1001051681
In the current release, these fields display appropriate values when the command
evweb logviewer is run on BL870c i2 platform.
In the previous release on BL870c i2 platform, whenever events generated by
the native indication provider is logged in the provider database, a record ID is
QXCR1001056641
associated with the logged record. To access or retrieve this record, the
getInstance method is supplied with the specific record ID. If the record ID is
not available in the provider database, the provider dumps core.
This defect is fixed in the current release. If the record ID supplied with the
getInstance method is not available in the provider database, the provider exits
gracefully without dumping core.
In the previous release on BL870c i2 platform, the directly attached storage disk
test command:
QXCR1001058688
#/opt/dasprovider/bin/Disk_Provider_test -d fails to generate events
for all subsequent directly attached storage disks available on the system if the first
instance of the disk is not supported by the
HPUXStorageNativeIndicationProviderModule.
10 HP-UX WBEM Direct Attached Storage provider release notes