HP-UX WBEM DAS Provider release notes (5900-2316, September 2012)

NOTE: Registering Storage Native Control Provider
NOTE: Registering the Storage WBEM Native Provider.
ERROR: The "configure" script for "WBEMP-Storage.STORAGE-PROV-RUN"
failed (exit code "1"). The script location was
"/var/adm/sw/products/WBEMP-Storage.2/STORAGE-PROV-RUN/configure".
Workaround: Uninstall the currently running DASProvider (where the problem is seen) and
install either DAS provider version B.11.31.1106 or B.11.31.1109.05.01.
When DAS provider B.11.31.1103.15 or later is installed on legacy Integrity systems, disk_em
and msamon_sas are not launched regardless of the diag mode.
HPUXDiskNativeIndicationProvider always natively monitors the hardware and generates
WBEM events. The reverse wrapper, DAS_WbemWrapperMonitor, and/or
MSA_WbemWrapperMonitor may be launched depending on the connected hardware. These
reverse wrappers convert the WBEM event to the corresponding EMS event.
The introduction of this native support adds to support the following EMS resource paths:
/storage/events/DAS_wrapper_wbem
/storage/events/MSA_wrapper_wbem
On the other hand, as the process for disk_em and msamon_sas are not launched, the
corresponding EMS resource paths are not monitored:
/storage/events/disks/default
/storage/events/enclosures/msamon_sas
Problem: There are no email alerts for the subscription.
Description: User do not receive email alerts for existing and new email subscriptions due to
database authorization issue in September 2011 release.
Workaround: There is no workaround for this problem.
Problem: When the first node of the hostname is changed to a name that has more than 8
characters, the DAS provider fails to report the events.
Workaround: To ensure DAS provider works as expected, change the first node of the hostname
to a name that has less than 8 characters.
The product has the following limitation:
It is a read-only provider and hence does not allow users to modify, create, or delete instances.
Related documentation
Table 9 lists the available documentation for the WBEM providers:
Table 9 WBEM provider Related Documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com
and
Information about HP WBEM Services
http://www.hp.com
http://www.openpegasus.org/uploads/40/3452/WBEMIndications.pdfOverview of the indication schema
The datasheets are available at the following location:Provider Datasheets
http://www.hp.com/go/hpux-networking-docs
Related documentation 15