HP-UX WBEM DAS Provider release notes (5900-2316, September 2012)

Table 7 Defects fixed in HP-UX 11i v3 OS (continued)
The upgrade of DAS provider does not retain user configurable values of config files.QXCR1001145740
Changes are made to ensure that the user configurable attributes value of config files get
retained after upgradation.
The install logs present under the /var/opt/ directory displays unwanted messages during
cold install for RAIDSA, SAS, DAS, and FC providers
QXCR1001133148
This defect is fixed in the current release. The createtable.sh script is modified to check
the cold install and database accordingly.
The DAS provider module crashes when it is enabled.QXCR1001141163
This issue is fixed in this release.
Defects fixed in version B.11.31.1203.07.02
Upgrade of provider fails on a machine that has a database with large number of record set
and the system runs out of memory while executing the query to fetch all records. The upgrade
fails with the following errors
QXCR1001188297
ERROR: database "DASPROVDB" already exists
ERROR: Operation : createdb DASPROVDB failed
This issue is fixed in this release.
Defects fixed in version B.11.31.1209.07.01
During the restart, the DAS provider may crash.QXCR1001110884
This issue is fixed in this release.
When the DAS provider having large number of records in the database is upgraded, the
provider upgrade fails.
QXCR1001200700
This issue is fixed in this release.
During multiple system reboot, past provider events get reported for the DAS provider.QXCR1001198841
This issue is fixed in this release. When the past provider events get reported, the following
warning message is seen in the provider log:
WARNING! Started processing old osel log files. Old events may get reported.
You can safely ignore this message.
The file descriptor leaks are seen in the DASProvider.QXCR1001211075
This issue is fixed in this release.
Known problems, workarounds, and limitations
The following known problems are for the current release:
After updating a system from HP-UX 11i Base OE B.11.31.1009 (September 2010) to HP-UX
11i Base OE B.11.31.1103 (March 2011) using update-ux(1M), the
WBEMP-Storage.STORAGE-PROV-RUN fileset is not configured. Trying to configure the fileset
using swconfig (1M) also fails.
The following is seen in the /var/adm/sw/swagent.log file:
* Running "configure" script for fileset
"WBEMP-Storage.STORAGE-PROV-RUN".
NOTE: Disabling old Disk Native Provider.
ERROR: PGC00617: Disabling the provider module... PGS00414:
Connection timed out.
NOTE: Removing old Disk Native Provider.
NOTE: PGC00614: Deleting the provider module... PGC00607: The
provider is deleted successfully.
NOTE: Creating the Disk log database
NOTE: Disk log database setup completed.
NOTE: Registering Storage WBEM Indication Provider schema
NOTE: Registering Storage WBEM Instance Provider schema
NOTE: Registering Storage WBEM Record Log Provider
14 HP-UX WBEM Direct Attached Storage provider release notes