HP-UX WBEM DAS Provider release notes (5900-2051, March 2012)

Table 7 Defects fixed in HP-UX 11i v3 OS (continued)
The upgrade of DAS provider does not retain user configurable values of config files.QXCR1001145740
Changes are made to ensure that the user configurable attributes value of config files get
retained after upgradation.
The install logs present under the /var/opt/ directory displays unwanted messages during
cold install for RAIDSA, SAS, DAS, and FC providers
QXCR1001133148
This defect is fixed in the current release. The createtable.sh script is modified to check
the cold install and database accordingly.
The DAS provider module crashes when it is enabled.QXCR1001141163
This issue is fixed in this release.
Known problems, workarounds and limitations
The following known problems are for the current release:
The HPUXStorageNativeProviderModule is not able to retrieve the serial number of the inserted
disk due to failure of SCSI command with DEVICE_NOT_READY error. The problem will be
fixed in the next release.
After updating a system from HP-UX 11i Base OE B.11.31.1009 (September 2010) to HP-UX
11i Base OE B.11.31.1103 (March 2011) using update-ux(1M), the
WBEMP-Storage.STORAGE-PROV-RUN fileset is not configured. Trying to configure the fileset
using swconfig (1M) also fails.
The following is seen in the /var/adm/sw/swagent.log file:
* Running "configure" script for fileset
"WBEMP-Storage.STORAGE-PROV-RUN".
NOTE: Disabling old Disk Native Provider.
ERROR: PGC00617: Disabling the provider module... PGS00414:
Connection timed out.
NOTE: Removing old Disk Native Provider.
NOTE: PGC00614: Deleting the provider module... PGC00607: The
provider is deleted successfully.
NOTE: Creating the Disk log database
NOTE: Disk log database setup completed.
NOTE: Registering Storage WBEM Indication Provider schema
NOTE: Registering Storage WBEM Instance Provider schema
NOTE: Registering Storage WBEM Record Log Provider
NOTE: Registering Storage Native Control Provider
NOTE: Registering the Storage WBEM Native Provider.
ERROR: The "configure" script for "WBEMP-Storage.STORAGE-PROV-RUN"
failed (exit code "1"). The script location was
"/var/adm/sw/products/WBEMP-Storage.2/STORAGE-PROV-RUN/configure".
Workaround: Uninstall the currently running DASProvider (where the problem is seen) and
install either DAS provider version B.11.31.1106 or B.11.31.1109.05.01.
When DAS provider B.11.31.1103.15 or later is installed on legacy Integrity systems, disk_em
and msamon_sas are not launched regardless of the diag mode.
HPUXDiskNativeIndicationProvider always natively monitors the hardware and generates
WBEM events. The reverse wrapper, DAS_WbemWrapperMonitor, and/or
MSA_WbemWrapperMonitor may be launched depending on the connected hardware. These
reverse wrappers convert the WBEM event to the corresponding EMS event.
The introduction of this native support adds to support the following EMS resource paths:
/storage/events/DAS_wrapper_wbem
/storage/events/MSA_wrapper_wbem
On the other hand, as the process for disk_em and msamon_sas are not launched, the
corresponding EMS resource paths are not monitored:
/storage/events/disks/default
/storage/events/enclosures/msamon_sas
14 HP-UX WBEM Direct Attached Storage provider release notes