HP-UX WBEM DAS Provider release notes (5900-1991, September 2011 release)

Table 7 Defects Fixed in HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the previous release, the memory leak is seen in
DiskPollerJob.cpp:performPolling() function. Delete in two return paths
were missing for a variable allocated on heap.
QXCR1001124484
This defect is fixed in the current release. Changes are made to delete the variable
in these two return paths.
In the previous release, the HPUXStorageIndicationProviderModule data
had junk values at the end in evweb o/p under "Error Details/Component Data".
QXCR1001053727
This defect is fixed in the current release. Void Pointer is passed to the EMS API
which fills the "Error Details/Component Data".
In the previous release, core file generated by cimprovagt, program terminated
with signal 11, resulting in segmentation fault.
QXCR1001051369
This defect is fixed in the current release.
Defects Fixed in version B.11.31.1109.06.02
For disk insertion event [event no :100] , the component details shown for the new disk is
wrong. The instance provider also shows wrong data for the inserted disk. This defect is seen
only for disk removal and insertion behind Raid cards when in HBA mode only.
QXCR1001149757
This defect is now fixed in DASProvider and the provider shows correct data in the event
details and in instance enumeration.
Known Problems, Workarounds, Limitations
The following known problems are for the current release:
An event gets generated when disks are removed/inserted into a system. The problem will
be fixed in the next release.
The HPUXStorageNativeProviderModule is not able to retrieve the serial number of the inserted
disk due to failure of SCSI command with DEVICE_NOT_READY error. The problem will be
fixed in the next release.
After updating a system from HP-UX 11i Base OE B.11.31.1009 (September 2010) to HP-UX
11i Base OE B.11.31.1103 (March 2011) using update-ux(1M), the
WBEMP-Storage.STORAGE-PROV-RUN fileset is not configured. Trying to configure the fileset
using swconfig (1M) also fails.
The following is seen in the /var/adm/sw/swagent.log file:
* Running "configure" script for fileset
"WBEMP-Storage.STORAGE-PROV-RUN".
NOTE: Disabling old Disk Native Provider.
ERROR: PGC00617: Disabling the provider module... PGS00414:
Connection timed out.
NOTE: Removing old Disk Native Provider.
NOTE: PGC00614: Deleting the provider module... PGC00607: The
provider is deleted successfully.
NOTE: Creating the Disk log database
NOTE: Disk log database setup completed.
NOTE: Registering Storage WBEM Indication Provider schema
NOTE: Registering Storage WBEM Instance Provider schema
NOTE: Registering Storage WBEM Record Log Provider
NOTE: Registering Storage Native Control Provider
NOTE: Registering the Storage WBEM Native Provider.
ERROR: The "configure" script for "WBEMP-Storage.STORAGE-PROV-RUN"
failed (exit code "1"). The script location was
"/var/adm/sw/products/WBEMP-Storage.2/STORAGE-PROV-RUN/configure".
Workaround: Uninstall the currently running DASProvider (where the problem is seen) and
install either DAS Provider version B.11.31.1106 or B.11.31.1109.05.01.
When DAS Provider B.11.31.1103.15 or later is installed on legacy Integrity systems, disk_em
and msamon_sas are not launched regardless of the diag mode.
Known Problems, Workarounds, Limitations 13