Table 7 Defects Fixed in HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the previous release, the HPUXStorageNativeIndicationProviderModule
does not support event 15 on legacy Integrity and BL870c i2 platforms.
QXCR1001097747
In the current release, the HPUXStorageNativeIndicationProviderModule
supports event 15 on legacy Integrity and BL870c i2 platforms.
In the previous release, the HPUXStorageNativeIndicationProviderModule
supports a constant polling interval of 20 minutes on legacy Integrity and BL870c
i2 platforms.
QXCR1001095319
In the current release, a new poller configuration file included in the
HPUXStorageNativeIndicationProviderModule allow customers to set the
polling interval on legacy Integrity and BL870c i2 platforms.
In the previous release, enumeration of the HP_DiskDrive class does not return
the component data as required.
QXCR1001091192
This defect is fixed in the current release and enumeration of the HP_DiskDrive
class returns the component data as required.
Defects Fixed in version B.11.31.1106
In the previous release, a core file was generated due to a memory corruption in
DAS provider.
QXCR1001095322
In the current release, this problem is fixed.
In the previous release DAS provider used to leak memory after every polling interval.QXCR1001124484
In the current release, this problem is fixed.
In the previous release, the DAS provider used semaphore with semid == 0 even
when it was created/used by other application and this affected the applications.
QXCR1001120981
This defect is fixed in the current release. DAS provider will not be using any
semaphonre. The usage of Semaphores has been replaced by a Mutex lock.
Defects Fixed in version B.11.31.1109
In the previous release, DASProvider consumes - health offline / online events instead
of status_change evm notifications. Event 100 and 101 will not be generated by
QXCR1001103479
the provider if the disks are behind FC/SAS card. Since events are not generated,
Disk instance provider does not refresh its cache. This results in displaying the disk
details even though the disk is removed or not online.
This defect is fixed in the current release. The disk online / offline events will be
generated for disks behind FC/SAS.
In the previous release, the DASProvider used semaphore with semid == 0 even
when it was created/used by other application and this affected the applications.
QXCR1001120981
This defect is fixed in the current release. DASProvider will not be using any
semaphonre. The usage of Semaphores has been replaced by a Mutex lock.
In the previous release, the HPUXStorageIndicationProviderModule registers to
disk_em, msamom, msamom_sas, gazemon monitors repeatedly every 5 minutes.
This causes a poll from these monitors which has to be avoided.
QXCR1001093716
This defect is fixed in the current release. Store the PID of the monitors in the provider
and register only when the PID changes that is when monitor has restarted.
In the previous release, the DASProvider used to crash while enabling/disabling.
This was due to the implementation of xml parser in SCSI decode which was
incorrect. This led to the scope issue with the XML parser code.
QXCR1001085108
This defect is fixed in the current release by resolving the scope issue.
12 HP-UX WBEM Direct Attached Storage Provider release notes