HP-UX WBEM DAS Provider release notes (5900-1778, September 2011)

NOTE: Removing old Disk Native Provider.
NOTE: PGC00614: Deleting the provider module... PGC00607: The
provider is deleted successfully.
NOTE: Creating the Disk log database
NOTE: Disk log database setup completed.
NOTE: Registering Storage WBEM Indication Provider schema
NOTE: Registering Storage WBEM Instance Provider schema
NOTE: Registering Storage WBEM Record Log Provider
NOTE: Registering Storage Native Control Provider
NOTE: Registering the Storage WBEM Native Provider.
ERROR: The "configure" script for "WBEMP-Storage.STORAGE-PROV-RUN"
failed (exit code "1"). The script location was
"/var/adm/sw/products/WBEMP-Storage.2/STORAGE-PROV-RUN/configure".
Workaround: Uninstall the currently running DASProvider (where the problem is seen) and
install either B.11.31.1106 or B.11.31.1109.05.01 DAS Provider version.
When DAS Provider B.11.31.1103.15 or later is installed on legacy Integrity systems, disk_em
and msamon_sas are never launched regardless of the diag mode.
HPUXDiskNativeIndicationProvider always monitors natively the hardware and generates
WBEM events. The reverse wrapper, DAS_WbemWrapperMonitor and/or
MSA_WbemWrapperMonitor, may be launched depending on the connected hardware.
These reverse wrappers convert the WBEM event to the corresponding EMS event.
The introduction of this native support adds to support the following EMS resource paths:
/storage/events/DAS_wrapper_wbem
/storage/events/MSA_wrapper_wbem
On the other hand, as the process for disk_em and msamon_sas are never launched, the
corresponding EMS resource paths are not monitored:
/storage/events/disks/default
/storage/events/enclosures/msamon_sas
The product has the following limitation:
It is a read-only provider and hence does not allow users to modify, create, or delete instances.
Related Documentation
Table 9 lists the available documentation for the WBEM providers:
Table 9 WBEM Provider Related Documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com
and
Information about HP WBEM Services
http://www.hp.com
http://www.openpegasus.org/uploads/40/3452/WBEMIndications.pdfOverview of the Indication Schema
Datasheets of all the providers are installed along with the product at the following
location on the system:/opt/<provider-name>/doc
Provider Datasheets
The datasheets are also available at the following location:
http://www.hp.com/go/hpux-networking-docs
Localized Version of the Software
The product is supported only in English locale (LANG=C). Behavior of the product is unpredictable
when LANG value is set to any other language code other than C. Documentation support for this
product is also available only in English locale.
14 HP-UX WBEM Direct Attached Storage Provider release notes