HP-UX WBEM DAS Provider release notes (5900-1778, September 2011)
Table 7 Defects Fixed in HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the current release on BL870c i2 platform, when the cimserver /
HPUXStorageNativeIndicationProviderModule is restarted, the Indication
Identifier is concatenated with a timestamp along with the event number and Index.
With this modification, the Indication Identifier can never be duplicated and all the
events generated by the provider are unique which gets logged in the evweb
database.
In the previous release, when the command evweb eventviewer is run on
BL870c i2 platform, the field Latest information on this event displays
incorrect location for the event details page.
QXCR1001083536
In the current release, when the command evweb eventviewer is run on BL870c
i2 platform, the field Latest information on this event displays correct
location http://bizsupport1.austin.hp.com/bizsupport/TechSupport/Document.jsp?
lang=en&cc=us&taskId=110&prodSeriesId=4183083&prodTypeId=18964&
prodSeriesId=4183083&objectID=c02293513 for the event details page.
In the previous release, the HPUXStorageNativeProviderModule leaks memory,
on legacy Integrity and BL870c i2 platforms, when the module receives an evm
notification about the IO subsystem status change.
QXCR1001075851
This defect is fixed in the current release.
Defects Fixed in version B.11.31.1103.15
In the previous release, after reinserting an internal disk , the CIMUtil does not
show the disk details.
QXCR1001103562
This defect is fixed in the current release. The details of the reinserted disk are
displayed correctly.
In the previous release, event numbers 7 and 8 were supported by the
HPUXStorageNativeIndicationProviderModule on legacy Integrity and
BL870c i2 platforms.
QXCR1001088668
In the current release, event numbers 7 and 8 are no longer supported by the
HPUXStorageNativeIndicationProviderModule on legacy Integrity and
BL870c i2 platforms. For information about the events, see http://
bizsupport1.austin.hp.com/bizsupport/TechSupport/SupportTaskIndex.jsp?lang=en&
cc=us&taskId=110&prodTypeId=18964&prodSeriesId=4183083
In the previous release, on legacy integrity and BL870c i2 platforms, when
excessive errors are generated from a faulty component, the DISKPROVDB database
QXCR1001083290
connection with the HPUXStorageNativeIndicationProviderModule exceeds
the threshold limit. This potentially leads to core dump.
In the current release, the defect is fixed and excessive errors generated from a
faulty component are handled appropriately.
In the previous release, the HPUXStorageNativeIndicationProviderModule
is not supported on legacy Integrity systems.
QXCR1001048147
In the current release, the HPUXStorageNativeIndicationProviderModule
is supported on legacy Integrity systems. The monitors disk_em and msamon_sas
no longer generate events on legacy Integrity systems.
The consolidated status provider displays the overall status of the IO subsystem
based on the GroupOperationalStatus property severity level. The severity
QXCR1001066416
levels associated for the GroupOperationalStatus property values during the
previous release and the current release are tabulated below.
Defects Fixed in This Version 11