Table 7 Defects Fixed in HP-UX 11i v3 OS (continued)
In the previous release on BL870c i2 platform, whenever events generated by the native
indication provider is logged in the provider database, a record ID is associated with the
QXCR1001056641
logged record. To access or retrieve this record, the getInstance method is supplied with
the specific record ID. If the record ID is not available in the provider database, the provider
dumps core.
This defect is fixed in the current release. If the record ID supplied with the getInstance
method is not available in the provider database, the provider exits gracefully without dumping
core.
In the previous release on BL870c i2 platform, the directly attached storage disk test
command:
QXCR1001058688
#/opt/dasprovider/bin/Disk_Provider_test -d fails to generate events for all
subsequent directly attached storage disks available on the system if the first instance of the
disk is not supported by the HPUXStorageNativeIndicationProviderModule.
This defect is fixed in the current release on BL870c i2 platform. The disk tests are enhanced
to send events for all the monitored paths even if the first instance of the disk is not supported
by the HPUXStorageNativeIndicationProviderModule.
In the previous release on HP-UX 11i v3 OS, enumeration of classes available in DAS Instance
provider and DAS Consolidated Status provider fails for a user with non-root privileges.
QXCR1001068706
This defect is fixed in the current release. Enumeration of classes available in DAS Instance
provider and DAS Consolidated Status provider is successful even for a normal user.
In the previous release on BL870c i2 platform, when an internal disk is removed from the
system events are not generated by the
QXCR1001056608
HPUXStorageNativeIndicationProviderModule. Due to this, the SMH application
displays incorrect status of the removed disk as OK.
This defect is fixed in the current release. The
HPUXStorageNativeIndicationProviderModule generates indication when an internal
disk is removed from the system, as a result the SMH application displays correct status of the
removed disk.
In the previous release on BL870c i2 platform, when the cimserver /
HPUXStorageNativeIndicationProviderModule is restarted, the Indication Identifier
QXCR1001078598
index is reset. If the evweb current database already has events with the same event number
or Indication Identifier index, such duplicate events are not logged in the evweb database.
When events with the same event number are being reported frequently, the events will be
logged in the /var/opt/sfm/log/event.log file and the syslog file.
In the current release on BL870c i2 platform, when the cimserver /
HPUXStorageNativeIndicationProviderModule is restarted, the Indication Identifier
is concatenated with a timestamp along with the event number and Index. With this
modification, the Indication Identifier can never be duplicated and all the events generated
by the provider are unique which gets logged in the evweb database.
In the previous release, when the command evweb eventviewer is run on BL870c i2
platform, the field Latest information on this event displays incorrect location for
the event details page.
QXCR1001083536
In the current release, when the command evweb eventviewer is run on BL870c i2
platform, the field Latest information on this event displays correct location http://
bizsupport1.austin.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&
taskId=110&prodSeriesId=4183083&prodTypeId=18964&prodSeriesId=4183083&
objectID=c02293513 for the event details page.
In the previous release, the HPUXStorageNativeProviderModule leaks memory, on
legacy Integrity and BL870c i2 platforms, when the module receives an evm notification
about the IO subsystem status change.
QXCR1001075851
This defect is fixed in the current release.
Known Problems, Workarounds, Limitations
The following known problem is for the current release:
10 HP-UX WBEM Direct Attached Storage Provider release notes