HP-UX WBEM DAS Indication Provider Datasheet, September 2011 Release

string ProbableCauseDescription
Inherited from CIM_AlertIndication
Provides additional information related to the
ProbableCause. This property corresponds to the first
sub-section of the “Probable Cause/Recommended
Action” field in the EMS event notification.
string[] RecommendedActions
Inherited from CIM_AlertIndication
Free form descriptions of the recommended actions to
take to resolve the cause of the notification. This property
corresponds to the sub-sections following the first sub-
section in the “Probable Cause/Recommended Action”
field in the EMS event notification.
string EventID
Inherited from CIM_AlertIndication
An instrumentation or provider specific value that
describes the underlying "real-world" event represented
by the Indication.
For example, 8
datetime EventTime
Inherited from CIM_AlertIndication
The time and date when the underlying event was first
detected. This property corresponds to the field “Event
time” in the EMS event notification.
For example, “yyyymmddhhmmss”
string SystemCreationClassName
Inherited from CIM_AlertIndication
The scoping System's CreationClassName for the
Provider generating this Indication.
For example, “CIM_UnitaryComputerSystem”
string SystemName
Inherited from CIM_AlertIndication
The scoping System's Name for the Provider that
generates this Indication. This property corresponds to
the “System” field of the EMS event notification.
For example, “xxx.india.hp.com”
string ProviderName
Inherited from CIM_AlertIndication
The name of the Provider that generates this Indication.
For example, "DiskIndicationProvider" for events from
disk_em monitor, "GazeIndicationProvider" for gazemon
monitor events, "MsaIndicationProvider" for msamon
monitor events, "MsaSASIndicationProvider" for
msamon_sas monitor events.
Properties of HP_AlertIndication
string Summary
Inherited from HP_AlertIndication
Short description of the reason for the indication. This
property corresponds to the “Summary” field in the EMS
event notification.
uint32 EventCategory
Inherited from HP_AlertIndication
Category for the event. This is a value map which is
intended to be used by the consumer to group events.
For example, 11-“I/O Adapter”
uint32 ActualEventThreshold
Inherited from HP_AlertIndication
Identifies the number of indications that have occurred to
meet the internal provider throttling configured for this
event. This property corresponds to the “Number of
Events” field, if present, in the EMS Event notification.
Boolean ClusterWideEvent
Inherited from HP_AlertIndication
Indicates whether this event is of interest to all cluster
members.
For example, false
string ProviderVersion
Inherited from HP_AlertIndication
The version of the provider that generates this indication.