HP-UX WBEM DAS (Direct Attached Storage) Provider Release Notes (766961-001, March 2014)

/storage/events/enclosures/msamon_sas
Problem:
The events are lost when diagnostic products are upgraded on a DRD cloned disk.
Description:
Prior to September 2012 release version of diagnostics product, the postgres 7.4.2 version
was supported. However version 8.4.8 is shipped from September 2012 release. Due to the
missing data compatibility between PostgreSQL version 7.4.2 (prior to September 2012) and
8.4.8 (September 2012 release or later) when diagnostics products are upgraded from prior
to September 2012 release to September 2012 web release and later, the postgres data
need to be migrated to 8.4.8 format. Data migration involves backup in 7.4.2 version using
the pg_dumpall and restore in 8.4.8 version using the psql operations. Both of these operations
requires a running postgres service. But in the DRD environment there is a limitation that no
service can be run on the cloned disk when products are either installed or upgraded. This
limits diagnostics product upgrade steps from taking the backup of the postgres 7.4.2 data.
As a result, the data such as events and error records is lost during such circumstances.
Workaround:
You can select any of the following two alternatives:
1. To install the product on the DRD cloned disk as a normal upgrade scenario. The scenario
will be same as fresh installation and user may refer to event.log for historical event data.
2. To have a seamless migration of the data from postgres 7.4.2 version. In this case, the
user is required to perform the manual steps listed in the Installation scenarios of Postgres
8.4.8 guide at: www.hp.com/go/hpux-diagnostics-sfm-docs.
Limitations
The product has the following limitation:
It is a read-only provider and hence does not allow users to modify, create, or delete instances.
Related documentation
Table 26 (page 20) lists the available documentation for the WBEM providers:
Table 26 WBEM provider Related Documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com and http://www.hp.comInformation about HP WBEM Services
WBEMIndicationsOverview of the indication schema
The datasheets are available at the following location: http://www.hp.com/
go/hpux-networking-docs
Provider Datasheets
Localized version of the software
The product is supported only in English locale (LANG=C). Behavior of the product is random and
variable, when LANG value is set to any other language code other than C. Documentation support
for this product is also available only in English locale.
20 DAS (Direct Attached Storage) provider release notes for March 2014 release