HP-UX WBEM DAS (Direct Attached Storage) Provider Release Notes (766961-001, March 2014)
Table 25 B.11.31.0909.01 (continued)
DescriptionDefect ID
This defect has been fixed in this release and the file diskaldata is not
created in the root directory of the system.
In the previous release, a core file is created randomly in the /var/opt/
wbem directory. Occurrence of this file does not affect normal working of the
product.
QXCR1000894271
This defect has been fixed in this release and the core file is not created in
the /var/opt/wbem directory.
Known problems, workaround, and limitations
Known problems
The following are the known issues, tabulated from multiple releases.
• Problem:
After updating a system from HP-UX 11i Base OE B.11.31.1009 (September 2010) to HP-UX
11i Base OE B.11.31.1103 (March 2011) using update-ux(1M), the
WBEMP-Storage.STORAGE-PROV-RUN fileset is not configured. Trying to configure the fileset
using swconfig (1M) also fails.
The following is seen in the /var/adm/sw/swagent.log file:
* Running "configure" script for fileset "WBEMP-Storage.STORAGE-PROV-RUN".
NOTE: Disabling old Disk Native Provider.
ERROR:
PGC00617: Disabling the provider module...
PGS00414: Connection timed out.
NOTE: Removing old Disk Native Provider.
NOTE:
PGC00614: Deleting the provider module...
PGC00607: The provider is deleted successfully.
NOTE: Creating the Disk log database
NOTE: Disk log database setup completed.
NOTE: Registering Storage WBEM Indication Provider schema
NOTE: Registering Storage WBEM Instance Provider schema
NOTE: Registering Storage WBEM Record Log Provider
NOTE: Registering Storage Native Control Provider
NOTE: Registering the Storage WBEM Native Provider.
ERROR: The "configure" script for "WBEMP-Storage.STORAGE-PROV-RUN" failed (exit code "1"). The script
location was “/var/adm/sw/products/WBEMP-Storage.2/STORAGE-PROV-RUN/configure”.
Workaround:
Uninstall the currently running DAS (Direct Attached Storage) Provider (where the problem is
seen) and install either DAS (Direct Attached Storage) Provider version B.11.31.1106 or
B.11.31.1109.05.01.
• When DAS (Direct Attached Storage) Provider B.11.31.1103.15 or later is installed on legacy
Integrity systems, disk_em and msamon_sas are not launched regardless of the diag mode.
HPUXDiskNativeIndicationProvider always natively monitors the hardware and generates
WBEM events. The reverse wrapper, DAS (Direct Attached Storage) _WbemWrapperMonitor,
and/or MSA_WbemWrapperMonitor may be launched depending on the connected hardware.
These reverse wrappers convert the WBEM event to the corresponding EMS event.
The introduction of this native support adds to support the following EMS resource paths:
/storage/events/DAS_wrapper_wbem
/storage/events/MSA_wrapper_wbem
On the other hand, as the process for disk_em and msamon_sas are not launched, the
corresponding EMS resource paths are not monitored:
/storage/events/disks/default
Known problems, workaround, and limitations 19