HP-UX WBEM DAS (Direct Attached Storage) Provider Release Notes (766961-001, March 2014)

Table 20 B.11.31.1103 (continued)
DescriptionDefect ID
In the previous release, the VirtualSystemSerialNo and
SystemSerialNo fields display incorrect value when the command evweb
logviewer is run on BL870c i2 platform.
QXCR1001051681
In the current release, these fields display appropriate values when the
command evweb logviewer is run on BL870c i2 platform.
In the previous release on BL870c i2 platform, whenever events generated
by the native indication provider is logged in the provider database, a record
QXCR1001056641
ID is associated with the logged record. To access or retrieve this record,
the getInstance method is supplied with the specific record ID. If the
record ID is not available in the provider database, the provider dumps core.
This defect has been fixed in this release.
If the record ID supplied with the getInstance method is not available in
the provider database, the provider exits gracefully without dumping core.
In the previous release on BL870c i2 platform, the directly attached storage
disk test command:
QXCR1001058688
#/opt/dasprovider/bin/Disk_Provider_test -d fails to generate
events for all subsequent directly attached storage disks available on the
system if the first instance of the disk is not supported by the
HPUXStorageNativeIndicationProviderModule.
This defect has been fixed in this release, on BL870c i2 platform.
The disk tests are enhanced to send events for all the monitored paths even
if the first instance of the disk is not supported by the
HPUXStorageNativeIndicationProviderModule.
In the previous release on HP-UX 11i v3 OS, enumeration of classes available
in DAS (Direct Attached Storage) Instance provider and DAS (Direct Attached
Storage) Consolidated Status provider fails for a user with non-root privileges.
QXCR1001068706
This defect has been fixed in this release.
Enumeration of classes available in DAS (Direct Attached Storage) Instance
provider and DAS (Direct Attached Storage) Consolidated Status provider
is successful even for a normal user.
In the previous release on BL870c i2 platform, when an internal disk is
removed from the system events are not generated by the
QXCR1001056608
HPUXStorageNativeIndicationProviderModule. Due to this, the
SMH (System Management Homepage) application displays incorrect status
of the removed disk as OK.
This defect has been fixed in this release.
The HPUXStorageNativeIndicationProviderModule generates
indication when an internal disk is removed from the system, as a result the
SMH (System Management Homepage) application displays correct status
of the removed disk.
In the previous release on BL870c i2 platform, when the cimserver /
HPUXStorageNativeIndicationProviderModule is restarted, the
QXCR1001078598
Indication Identifier index is reset. If the evweb current database already
has events with the same event number or Indication Identifier index, such
duplicate events are not logged in the evweb database. When events with
the same event number are being reported frequently, the events will be
logged in the /var/opt/sfm/log/event.log file and the syslog file.
In the current release on BL870c i2 platform, when the cimserver /
HPUXStorageNativeIndicationProviderModule is restarted, the
Indication Identifier is concatenated with a timestamp along with the event
number and Index. With this modification, the Indication Identifier can never
be duplicated and all the events generated by the provider are unique which
gets logged in the evweb database.
Defects fixed in various versions 15