HP-UX WBEM DAS (Direct Attached Storage) Provider Release Notes (766961-001, March 2014)

Table 18 B.11.31.1103.15 (continued)
DescriptionDefect ID
Table 19 QXCR1001066416 (continued)
Earlier Severity
LevelCurrent Severity Level
Subsystem
GroupOperationalStatus
Unknown(0) and
No Contact(12).
Stopping(9)
In Service(11)
Dormant(15)
Power Mode(18)
Has higher severity
level than the states
Has less severity level than
the states OK(2) and
Completed(17).
Unknown(0)
No Contact(12)
OK(2) and
Completed(17).
Has the lowest
severity level.
Has the highest severity
level.
OK(2)
Completed(17)
In the previous release,
HPUXStorageNativeIndicationProviderModule does not support
event 15 on legacy Integrity and BL870c i2 platforms.
QXCR1001097747
In the current release,
HPUXStorageNativeIndicationProviderModule supports event 15
on legacy Integrity and BL870c i2 platforms.
In the previous release,
HPUXStorageNativeIndicationProviderModule supports a constant
polling interval of 20 minutes on legacy Integrity and BL870c i2 platforms.
QXCR1001095319
In the current release, a new poller configuration file included in
HPUXStorageNativeIndicationProviderModule allow customers to
set the polling interval on legacy Integrity and BL870c i2 platforms.
In the previous release, enumeration of HP_DiskDrive class does not return
the component data as required.
QXCR1001091192
This defect has been fixed in this release and enumeration of HP_DiskDrive
class returns the component data as required.
Defect fixes in B.11.31.1103 version
Table 20 B.11.31.1103
DescriptionDefect ID
In the previous release on BL870c i2 platform, the evweb logviewer
command displays incorrect or incomplete event details for secondary storage
QXCR1001042481
devices. As a result, users will be unable to locate faulty device attached to
the system.
This defect has been fixed in this release.
A new field Hardware Path is added in the evweb logviewer output.
This field provides complete hardware path of the failing hardware.
In the previous release on BL870c i2 platform, the
HPUXStorageNativeIndicationProviderModule fails to generate
esdisk/escsi related events on the platform.
QXCR1001042893
In the current release, this defect is fixed and the
HPUXStorageNativeIndicationProviderModule generate
esdisk/escsi related events on BL870c i2 platform.
14 DAS (Direct Attached Storage) provider release notes for March 2014 release