HP-UX WBEM DAS (Direct Attached Storage) Provider Release Notes (766961-001, March 2014)

Defect fixes in B.11.31.1203.04.01 version
Table 14 B.11.31.1203.04.01
DescriptionDefect ID
The HPUXStorageNativeProvider does not generate Event #100 when
a disk is inserted. Retry logic is included, to send SCSI enquiry command if
QXCR1001134066
there is any failure in retrieving disk attributes. Event #100 is now being
generated when a disk is inserted.
All the non filled properties in CIMUtil/wbemexec query appears as boolean.
For example,
QXCR1001088998
NAME="CapabilityDescriptions" TYPE="boolean">
The properties of the following DataType is incorrect:
NAME="EnabledState" TYPE="sint32">
NAME="RequestedState" TYPE="sint32">
NAME="EnabledDefault" TYPE="sint32">
This issue is fixed in the current release. Only the filled in data is displayed.
The non filled data in CIMUtil/wbemexec query increases the network traffic,
therefore it is not displayed. The properties of all DataType is corrected.
When cimserver is shutdown, a core is observed.QXCR1001110569
This issue is fixed in the current release.
Currently in DAS (Direct Attached Storage) Provider, the event processing
stops if any of the attributes fail when an enquiry command to disk is run.
QXCR1001130598
This issue is fixed and the design of DAS (Direct Attached Storage) Provider
is now changed. The event generation logic is made resilient to handle
retrieval failures of all the properties except Vendor ID, Product ID, and
firmware version
The upgrade of DAS (Direct Attached Storage) Provider does not retain user
configurable values of config files.
QXCR1001145740
Changes are made to ensure that the user configurable attributes value of
config files get retained after upgradation.
The install logs present under the /var/opt/ directory displays unwanted
messages during cold install for RAIDSA, SAS, DAS (Direct Attached Storage)
, and FC (Fibre-Channel) providers
QXCR1001133148
This defect has been fixed in this release.
The createtable.sh script is modified to check the cold install and
database accordingly.
DAS (Direct Attached Storage) Provider module crashes when it is enabled.QXCR1001141163
This issue has been fixed in this release.
Defect fixes in B.11.31.1109.06.02 version
Table 15 B.11.31.1109.06.02
DescriptionDefect ID
For disk insertion event [event no :100] , the component details shown for
the new disk is wrong. The instance provider also shows wrong data for the
QXCR1001149757
inserted disk. This defect is seen only for disk removal and insertion behind
Raid cards when in HBA mode only.
This defect is now fixed in DAS (Direct Attached Storage) Provider and the
provider shows correct data in the event details and in instance enumeration.
Defects fixed in various versions 11