Problem: On a vpar machine, when MCA happens there is no MCA record logged in
/var/tombstones directory.
Resolution: This problem is fixed.
• QXCR1001166085
The vacuumBinaryIA fails to perform.
Problem: Due to incorrect password, vacuumBinaryIA fails to perform its operations.
Resolution: This problem is fixed.
Installing HP-UX ProviderSvcsBase
The latest ProviderSvcsBase depot is available for download on the OE media.
For more information on installing and configuring these products, see the HP-UX ProviderSvcsBase
Administrator's Guide available at the following location: http://www.hp.com/go/hpux-wbem-docs
Hardware Requirements
Currently, this product is supported on all HP Integrity systems.
Software Requirements and OS Support
The provider requires certain software products to be installed on the managed system.
Table 2 (page 5) lists the software product requirement for the provider.
Table 2 ProviderSvcsBase Software Requirement
Product VersionProduct
HP-UX 11i v3 March 2009 release or laterEvent Manager (EVM)
September 2011 release or laterSysFaultMgmt
A.02.09 or laterWBEM Services
A.05.00.09.01, March 2011 release or laterSysMgmtPlus
NOTE: On legacy Integrity systems running HP-UX 11i v3, both dialogd and oserrlogd
co-exist from March 2009. The OnlineDiag product, if installed, must be March 2009 or later
version.
Disk Space Requirement
Table 3 (page 5) lists the amount of disk space required to install theProviderSvcsBase
bundle products:
Table 3 Disk Space Requirement
Disk SpaceProduct
85 MBProviderSvcsBase products with the Health
Test sub-product.
15 MBHealth Test sub-product only
Known Problems, Workarounds, Limitations
Following known problem is applicable for the current release:
Problem: If the permission for /tmp and /var/tmp directories are changed during HP-UX
installation phase, the sfmdb user cannot write temporary files. As a result, WBEM events are not