Veritas Volume Manager 5.0.1 Troubleshooting Guide, HP-UX 11i v3, First Edition, November 2009

V-5-1-768
VxVM vxconfigd NOTICE V-5-1-768 Offlining config copy number on
diskdisk: Reason: reason
Description:
An I/O error caused the indicated configuration copy to be disabled. This is a
notice only, and does not normally imply serious problems, unless this is the last
active configuration copy in the disk group.
Recommended action:
Consider replacing the indicated disk, since this error implies that the disk has
deteriorated to the point where write errors cannot be repaired automatically.
The error can also result from transient problems with cabling or power.
V-5-1-809
VxVM vxplex ERROR V-5-1-809 Plex plex in volume volume is locked by
another utility.
Description:
The vxplex command fails because a previous operation to attach a plex did not
complete. The vxprint command should show that one or both of the temporary
and persistent utility fields (TUTIL0 and PUTIL0) of the volume and one of its
plexes are set.
Recommended action:
If the vxtask list command does not show a task running for the volume, use
the vxmend command to clear the TUTIL0 and PUTIL0 fields for the volume and
all its components for which these fields are set:
# vxmend -g diskgroup clear all volume plex ...
V-5-1-923
VxVM vxplex ERROR V-5-1-923 Record volume is in disk group diskgroup1
plex is in group diskgroup2.
Description:
An attempt was made to snap back a plex from a different disk group.
Recommended action:
Move the snapshot volume into the same disk group as the original volume.
93Error messages