Veritas Volume Manager 5.0.1 Troubleshooting Guide, HP-UX 11i v3, First Edition, November 2009
Figure 1-1
Main plex state cycle
PS: CLEAN
PKS: DISABLED
PS: ACTIVE
PKS: ENABLED
Start up
(vxvol start)
Shut down
(vxvol stop)
PS = plex state
PKS = plex kernel state
For more information about plex states, see the Veritas Volume Manager
Administrator’s Guide.
At system startup, volumes are started automatically and the vxvol start task
makes all CLEAN plexes ACTIVE. At shutdown, the vxvol stop task marks all
ACTIVE plexes CLEAN. If all plexes are initially CLEAN at startup, this indicates
that a controlled shutdown occurred and optimizes the time taken to start up the
volumes.
Figure 1-2 shows additional transitions that are possible between plex states as
a result of hardware problems, abnormal system shutdown, and intervention by
the system administrator.
Recovering from hardware failure
The plex state cycle
12