Veritas Volume Manager 5.0.1 Troubleshooting Guide, HP-UX 11i v3, First Edition, November 2009
The DRL or RAID-5 log for the named volume was detached as a result of a disk
failure, or as a result of the administrator removing a disk with vxdg -k rmdisk.
A failing disk is indicated by a “Detached disk” message.
Recommended action:
If the log is mirrored, hot-relocation tries to relocate the failed log automatically.
Use either vxplex dis or vxsd dis to remove the failing logs. Then, use vxassist
addlog to add a new log to the volume.
See the vxassist(1M) manual page.
V-5-1-526
VxVM vxconfigd NOTICE V-5-1-526 Detached plex plex in volume volume
Description:
The specified plex was disabled as a result of a disk failure, or as a result of the
administrator removing a disk with vxdg -k rmdisk. A failing disk is indicated
by a “Detached disk” message.
Recommended action:
If hot-relocation is enabled, Veritas Volume Manager objects affected by the disk
failure are taken care of automatically. Mail is sent to root indicating what actions
were taken by VxVM and what further actions the administrator should take.
V-5-1-527
VxVM vxconfigd NOTICE V-5-1-527 Detached subdisk subdisk in volume
volume
Description:
The specified subdisk was disabled as a result of a disk failure, or as a result of
the administrator removing a disk with vxdg -k rmdisk. A failing disk is indicated
by a “Detached disk” message.
Recommended action:
If hot-relocation is enabled, Veritas Volume Manager objects affected by the disk
failure are taken care of automatically. Mail is sent to root indicating what actions
were taken by VxVM and what further actions the administrator should take.
V-5-1-528
VxVM vxconfigd NOTICE V-5-1-528 Detached volume volume
Description:
83Error messages
Types of messages