Veritas Volume Manager 5.0.1 Troubleshooting Guide, HP-UX 11i v3, First Edition, November 2009

To restore RAID-5 logging to a RAID-5 volume, create a new log plex and attach
it to the volume.
V-5-0-216
VxVM vxio WARNING V-5-0-216 mod_install returned errno
Description:
A call made to the operating system mod_install function to load the vxio driver
failed.
Recommended action:
Check for additional console messages that may explain why the load failed. Also
check the console messages log file for any additional messages that were logged
but not displayed on the console.
V-5-0-237
VxVM vxio WARNING V-5-0-237 object subdisk detached from RAID-5 volume
at column column offset offset
Description:
A subdisk was detached from a RAID-5 volume because of the failure of a disk or
an uncorrectable error occurring on that disk.
Recommended action:
Check for other console error messages indicating the cause of the failure. Replace
a failed disk as soon as possible.
V-5-0-243
VxVM vxio WARNING V-5-0-243 Overlapping mirror plex detached from
volume volume
Description:
An error has occurred on the last complete plex in a mirrored volume. Any sparse
mirrors that map the failing region are detached so that they cannot be accessed
to satisfy that failed region inconsistently.
Recommended action:
The message indicates that some data in the failing region may no longer be stored
redundantly.
73Error messages
Types of messages