Veritas Volume Manager 5.0.1 Troubleshooting Guide, HP-UX 11i v3, First Edition, November 2009

Check for other console error messages that may provide additional information
about the failure.
V-5-0-108
VxVM vxio WARNING V-5-0-108 Device major, minor: Received spurious
close
Description:
A close was received for an object that was not open. This can only happen if the
operating system is not correctly tracking opens and closes.
Recommended action:
No action is necessary; the system will continue.
V-5-0-110
VxVM vxdmp NOTICE V-5-0-110 disabled controller controller_name
connected to disk array disk_array_serial_number
Description:
All paths through the controller connected to the disk array are disabled. This
usually happens if a controller is disabled for maintenance.
Recommended action:
No recovery procedure is required.
V-5-0-111
VxVM vxdmp NOTICE V-5-0-111 disabled dmpnode dmpnode_device_number
Description:
A Dynamic Multipathing (DMP) node has been marked disabled in the DMP
database. It will no longer be accessible for further IO requests. This occurs when
all paths controlled by a DMP node are in the disabled state, and therefore
inaccessible.
Recommended action:
Check hardware or enable the appropriate controllers to enable at least one path
under this DMP node.
V-5-0-112
VxVM vxdmp NOTICE V-5-0-112 disabled path path_device_number belonging
to dmpnode dmpnode_device_number
Error messages
Types of messages
68