Veritas Volume Manager 5.0.1 Troubleshooting Guide, HP-UX 11i v3, First Edition, November 2009
VxVM vxio WARNING V-5-0-2 object_type object_name
blockoffset:Uncorrectable write error ...
Description:
A read or write operation from or to the specified Veritas Volume Manager object
failed. An error is returned to the application.
Recommended action:
These errors may represent lost data. Data may need to be restored and failed
media may need to be repaired or replaced. Depending on the type of object failing
and on the type of recovery suggested for the object type, an appropriate recovery
operation may be necessary.
V-5-0-4
VxVM vxio WARNING V-5-0-4 Plex plex detached from volume volume
Description:
An uncorrectable error was detected by the mirroring code and a mirror copy was
detached.
This message may also appear during a plex detach operation in a cluster.
Recommended action:
To restore redundancy, it may be necessary to add another mirror. The disk on
which the failure occurred should be reformatted or replaced.
If this message appears during a plex detach operation in a cluster, no action is
required.
V-5-0-34
VxVM vxdmp NOTICE V-5-0-34 added disk array disk_array_serial_number
Description:
A new disk array has been added to the host.
Recommended action:
No recovery procedure is required.
V-5-0-35
VxVM vxdmp NOTICE V-5-0-35 Attempt to disable controller
controller_name failed. Rootdisk has just one enabled path.
Description:
Error messages
Types of messages