Veritas Volume Manager 5.0.1 Troubleshooting Guide, HP-UX 11i v3, First Edition, November 2009

salcontact=no
V-5-1-4625
VxVM vxassist WARNING V-5-1-4625 SAL authentication failed...
Description:
The SAN Access Layer (SAL) rejects the credentials that are supplied by the
vxassist command.
Recommended action:
If connection to SAL is desired, use the vxspcshow command to set a valid user
name and password. Otherwise, suppress communication between vxassist and
SAL by adding the following line to the vxassist defaults file (usually
/etc/default/vxassist):
salcontact=no
V-5-1-5150
VxVM vxassist ERROR V-5-1-5150 Insufficient number of active snapshot
mirrors in snapshot_volume.
Description:
An attempt to snap back a specified number of snapshot mirrors to their original
volume failed.
Recommended action:
Specify a number of snapshot mirrors less than or equal to the number in the
snapshot volume.
V-5-1-5160
VxVM vxplex ERROR V-5-1-5160 Plex plex not associated to a snapshot
volume.
Description:
An attempt was made to snap back a plex that is not from a snapshot volume.
Recommended action:
Specify a plex from a snapshot volume.
V-5-1-5161
VxVM vxplex ERROR V-5-1-5161 Plex plex not attached.
113Error messages
Types of messages