Veritas Volume Manager 5.0.1 Troubleshooting Guide, HP-UX 11i v3, First Edition, November 2009

V-5-1-4277
VxVM vxconfigd ERROR V-5-1-4277 cluster_establish: CVM protocol
version out of range
Description:
When a node joins a cluster, it tries to join at the protocol version that is stored
in its volboot file. If the cluster is running at a different protocol version, the
master rejects the join and sends the current protocol version to the slave. The
slave re-tries with the current version (if that version is supported on the joining
node), or the join fails.
Recommended action:
Make sure that the joining node has a Veritas Volume Manager release installed
that supports the current protocol version of the cluster.
V-5-1-4551
VxVM vxconfigd ERROR V-5-1-4551 dg_move_recover: can’t locate disk(s),
giving up
Description:
Disks involved in a disk group move operation cannot be found, and one of the
specified disk groups cannot be imported.
Recommended action:
Manual use of the vxdg recover command may be required to clean the disk
group to be imported.
See Recovering from an incomplete disk group move on page 27.
V-5-1-4620
VxVM vxassist WARNING V-5-1-4620 Error while retrieving information
from SAL
Description:
The vxassist command does not recognize the version of the SAN Access Layer
(SAL) that is being used, or detects an error in the output from SAL.
Recommended action:
If a connection to SAL is desired, ensure that the correct version of SAL is installed
and configured correctly. Otherwise, suppress communication between vxassist
and SAL by adding the following line to the vxassist defaults file (usually
/etc/default/vxassist):
Error messages
Types of messages
112