Veritas Volume Manager 5.0.1 Administrator's Guide, HP-UX 11i v3, First Edition, November 2009
Table 15-1
Rule definitions in Storage Expert (continued)
DescriptionRule
Checks for RAID-5 volumes that do not have an associated
log.
vxse_raid5log1
Checks for recommended minimum and maximum RAID-5
log sizes.
vxse_raid5log2
Checks for large RAID-5 volumes that do not have a mirrored
RAID-5 log.
vxse_raid5log3
Checks the redundancy of volumes.vxse_redundancy
Checks that all root mirrors are set up correctly.vxse_rootmir
Checks that the number of spare disks in a disk group is
within the VxVM “Best Practices” thresholds.
vxse_spares
Checks for stripe volumes whose stripe unit is not a multiple
of the default stripe unit size.
vxse_stripes1
Checks for stripe volumes that have too many or too few
columns.
vxse_stripes2
Checks for volumes and plexes that are in various states,
such as:
■ disabled plexes
■ detached plexes
■ stopped volumes
■ disabled volumes
■ disabled logs
■ failed plexes
■ volumes needing recovery
vxse_volplex
You can use the list and check keywords to show what attributes are available
for a rule and to display the default values of these attributes.
See “Running a rule” on page 508.
Table 15-2 lists the available rule attributes and their default values.
517Using Storage Expert
Identifying configuration problems using Storage Expert