Veritas Volume Manager 5.0 Troubleshooting Guide, HP-UX 11i v3, First Edition, May 2008

96 Error messages
Understanding messages
Action: If a connection to SAL is desired, ensure that the correct version of
SAL is installed and configured correctly. Otherwise, suppress
communication between
vxassist and SAL by adding the following line to
the
vxassist defaults file (usually /etc/default/vxassist):
salcontact=no
V-5-1-4625
VxVM vxassist WARNING V-5-1-4625 SAL authentication failed...
Description: The SAN Access Layer (SAL) rejects the credentials that are
supplied by the
vxassist command.
Action: If connection to SAL is desired, use the vxspcshow command to set a
valid user name and password. Otherwise, suppress communication
between
vxassist and SAL by adding the following line to the vxassist
defaults file (usually /etc/default/vxassist):
salcontact=no
V-5-1-5150
VxVM vxassist ERROR V-5-1-5150 Insufficient number of active
snapshot mirrors in
snapshot_volume
.
Description: An attempt to snap back a specified number of snapshot
mirrors to their original volume failed.
Action: Specify a number of snapshot mirrors less than or equal to the
number in the snapshot volume.
V-5-1-5160
VxVM vxplex ERROR V-5-1-5160 Plex
plex
not associated to a snapshot
volume.
Description: An attempt was made to snap back a plex that is not from a
snapshot volume.
Action: Specify a plex from a snapshot volume.
V-5-1-5161
VxVM vxplex ERROR V-5-1-5161 Plex
plex
not attached.
Description: An attempt was made to snap back a detached plex.
Action: Reattach the snapshot plex to the snapshot volume.