Veritas Volume Manager 5.0 Troubleshooting Guide, HP-UX 11i v3, First Edition, May 2008
84 Error messages
Understanding messages
V-5-1-2197
VxVM vxconfigd ERROR V-5-1-2197 node
N
: missing vxconfigd
■ Description: The vxconfigd daemon is not running on the indicated
cluster node.
■ Action: Restart the vxconfigd daemon.
V-5-1-2198
VxVM vxconfigd ERROR V-5-1-2198 node
N
: vxconfigd not ready
■ Description: The vxconfigd daemon is not responding properly in a
cluster.
■ Action: Stop and restart the vxconfigd daemon on the node indicated.
V-5-1-2274
VxVM vxconfigd ERROR V-5-1-2274 volume:vxconfigd cannot boot-start
RAID-5 volumes
■ Description: A volume that vxconfigd should start immediately upon
booting the system (that is, the volume for the /usr file system) has a RAID-
5 layout. The /usr file system should never be defined on a RAID-5 volume.
■ Action: It is likely that the only recovery for this is to boot VxVM from a
network-mounted root file system (or from a CD-ROM), and reconfigure the
/usr file system to be defined on a regular non-RAID-5 volume.
V-5-1-2290
VxVM vxdmpadm ERROR V-5-1-2290 Attempt to enable a controller that
is not available
■ Description: This message is returned by the vxdmpadm utility when an
attempt is made to enable a controller that is not working or is not
physically present.
■ Action: Check hardware and see if the controller is present and whether I/O
can be performed through it.