Veritas Volume Manager 5.0 Troubleshooting Guide, HP-UX 11i v3, First Edition, May 2008

63Error messages
Understanding messages
Action: To restore RAID-5 logging to a RAID-5 volume, create a new log plex
and attach it to the volume.
V-5-0-216
VxVM vxio WARNING V-5-0-216 mod_install returned errno
Description: A call made to the operating system mod_install function to
load the vxio driver failed.
Action: Check for additional console messages that may explain why the
load failed. Also check the console messages log file for any additional
messages that were logged but not displayed on the console.
V-5-0-237
VxVM vxio WARNING V-5-0-237
object
subdisk detached from RAID-5 volume
at column column offset offset
Description: A subdisk was detached from a RAID-5 volume because of the
failure of a disk or an uncorrectable error occurring on that disk.
Action: Check for other console error messages indicating the cause of the
failure. Replace a failed disk as soon as possible.
V-5-0-243
VxVM vxio WARNING V-5-0-243 Overlapping mirror plex detached from
volume volume
Description: An error has occurred on the last complete plex in a mirrored
volume. Any sparse mirrors that map the failing region are detached so that
they cannot be accessed to satisfy that failed region inconsistently.
Action: The message indicates that some data in the failing region may no
longer be stored redundantly.
V-5-0-244
VxVM vxdmp NOTICE V-5-0-244 Path failure on major/minor
Description: A path under the control of the DMP driver failed. The device
major and minor numbers of the failed device is supplied in the message.
Action: None.