62 Error messages
Understanding messages
group. The log re-initializes on the new drive. Finally force the failed
volume into an active state and recover the data.
V-5-0-168
VxVM vxio WARNING V-5-0-168 Failure in RAID-5 logging operation
■ Description: Indicates that a RAID-5 log has failed.
■ Action: To restore RAID-5 logging to a RAID-5 volume, create a new log plex
and attach it to the volume.
V-5-0-181
VxVM vxio WARNING V-5-0-181 Illegal vminor encountered
■ Description: An attempt was made to open a volume device before
vxconfigd loaded the volume configuration.
■ Action: None; under normal startup conditions, this message should not
occur. If necessary, start VxVM and re-attempt the operation.
V-5-0-194
VxVM vxio WARNING V-5-0-194 Kernel log full: volume detached
■ Description: A plex detach failed because the kernel log was full. As a result,
the mirrored volume will become detached.
■ Action: It is unlikely that this condition ever occurs. The only corrective
action is to reboot the system.
V-5-0-196
VxVM vxio WARNING V-5-0-196 Kernel log update failed: volume detached
■ Description: Detaching a plex failed because the kernel log could not be
flushed to disk. As a result, the mirrored volume became detached. This may
be caused by all the disks containing a kernel log going bad.
■ Action: Repair or replace the failed disks so that kernel logging can once
again function.
V-5-0-207
VxVM vxio WARNING V-5-0-207 log object object_name detached from
RAID-5 volume
■ Description: Indicates that a RAID-5 log has failed.