Veritas Volume Manager 5.0 Troubleshooting Guide Guide (September 2006)

62 Error messages
Understanding messages
V-5-0-181
VxVM vxio WARNING V-5-0-181 Illegal vminor encountered
Description: An attempt was made to open a volume device before vxconfigd
loaded the volume configuration.
Action: None; under normal startup conditions, this message should not occur. If
necessary, start VxVM and re-attempt the operation.
V-5-0-194
VxVM vxio WARNING V-5-0-194 Kernel log full: volume detached
Description: A plex detach failed because the kernel log was full. As a result, the
mirrored volume will become detached.
Action: It is unlikely that this condition ever occurs. The only corrective action is to
reboot the system.
V-5-0-196
VxVM vxio WARNING V-5-0-196 Kernel log update failed: volume detached
Description: Detaching a plex failed because the kernel log could not be flushed to
disk. As a result, the mirrored volume became detached. This may be caused by all
the disks containing a kernel log going bad.
Action: Repair or replace the failed disks so that kernel logging can once again
function.
V-5-0-207
VxVM vxio WARNING V-5-0-207 log object object_name detached from
RAID-5 volume
Description: Indicates that a RAID-5 log has failed.
Action: To restore RAID-5 logging to a RAID-5 volume, create a new log plex and
attach it to the volume.
V-5-0-216
VxVM vxio WARNING V-5-0-216 mod_install returned errno
Description: A call made to the operating system mod_install function to load
the vxio driver failed.
Action: Check for additional console messages that may explain why the load failed.
Also check the console messages log file for any additional messages that were
logged but not displayed on the console.