Veritas Volume Manager 5.0 Troubleshooting Guide Guide (September 2006)
58 Error messages
Understanding messages
V-5-0-34
VxVM vxdmp NOTICE V-5-0-34 added disk array disk_array_serial_number
■ Description: A new disk array has been added to the host.
■ Action: None.
V-5-0-35
VxVM vxdmp NOTICE V-5-0-35 Attempt to disable controller
controller_name failed. Rootdisk has just one enabled path.
■ Description: An attempt is being made to disable the one remaining active path to the
root disk controller.
■ Action: The path cannot be disabled.
V-5-0-55
VxVM vxio WARNING V-5-0-55 Cannot find device number for boot_path
■ Description: The boot path retrieved from the system PROMs cannot be converted to
a valid device number.
■ Action: Check your PROM settings for the correct boot string.
V-5-0-106
VxVM vxio WARNING V-5-0-106 detaching RAID-5 volume
■ Description: Either a double-failure condition in the RAID-5 volume has been
detected in the kernel or some other fatal error is preventing further use of the array.
■ Action: If two or more disks have been lost due to a controller or power failure, use
the
vxrecover utility to recover them once they have been re-attached to the system.
Check for other console error messages that may provide additional information
about the failure.
V-5-0-108
VxVM vxio WARNING V-5-0-108 Device major, minor: Received spurious
close
■ Description: A close was received for an object that was not open. This can only
happen if the operating system is not correctly tracking opens and closes.
■ Action: No action is necessary; the system will continue.