Veritas Volume Manager 5.0 Administrator's Guide (September 2006)
447Using Storage Expert
Rule definitions and attributes
vxse_drl1 mirror_threshold 1g (1GB) Large mirror threshold size. Warn if a
mirror is larger than this and does not
have an attached DRL log.
vxse_drl2 large_mirror_size 20g (20GB) Large mirror-stripe threshold size.
Warn if a mirror-stripe volume is
larger than this.
vxse_host - - No user-configurable variables.
vxse_mirstripe large_mirror_size
nsd_threshold
1g (1GB)
8
Large mirror-stripe threshold size.
Warn if a mirror-stripe volume is
larger than this.
Large mirror-stripe number of
subdisks threshold. Warn if a mirror-
stripe volume has more subdisks than
this.
vxse_raid5 too_narrow_raid5
too_wide_raid5
4
8
Minimum number of RAID-5
columns. Warn if actual number of
RAID-5 columns is less than this.
Maximum number of RAID-5
columns. Warn if the actual number
of RAID-5 columns is greater than
this.
vxse_raid5log1 - - No user-configurable variables.
vxse_raid5log2 r5_max_size
r5_min_size
1g (1GB)
64m (64MB)
Maximum RAID-5 log check size.
Warn if a RAID-5 log is larger than
this.
Minimum RAID-5 log check size.
Warn if a RAID-5 log is smaller than
this.
vxse_raid5log3 large_vol_size 20g (20GB) Large RAID-5 volume threshold
size. Warn if a RAID-5 volume with
a non-mirrored RAID-5 log is larger
than this.
Table 15-2 Rule attributes and default attribute values
Rule Attribute Default value Description