VERITAS Volume Manager 4.1 Troubleshooting Guide

Error Messages
Understanding Messages
Chapter 672
V-5-0-145
VxVM vxio WARNING V-5-0-145 DRL volume volume is detached
Description: A Dirty Region Logging volume became detached because a DRL log entry
could not be written. If this is due to a media failure, other errors may have been logged to
the console.
Action: The volume containing the DRL log continues in operation. If the system fails
before the DRL has been repaired, a full recovery of the volume’s contents may be
necessary and will be performed automatically when the system is restarted. To recover
from this error, use the vxassistaddlog command to add a new DRL log to the volume.
V-5-0-146
VxVM vxdmp NOTICE V-5-0-146 enabled controller controller_name connected to disk
array disk_array_serial_number
Description: All paths through the controller connected to the disk array are enabled. This
usually happens if a controller is enabled after maintenance.
Action: None.
V-5-0-147
VxVM vxdmp NOTICE V-5-0-147 enabled dmpnode dmpnode_device_number
Description: A DMP node has been marked enabled in the DMP database. This happens
when at least one path controlled by the DMP node has been enabled.
Action: None.
V-5-0-148
VxVM vxdmp NOTICE V-5-0-148 enabled path path_device_number belonging to dmpnode
dmpnode_device_number
Description: A path has been marked enabled in the DMP database. This path is
controlled by the DMP node indicated by the specified device number. This happens if a
previously disabled path has been repaired, the user has reconfigured the DMP database
using the vxdctl(1M) command, or the DMP database has been reconfigured
automatically.
Action: None.
V-5-0-164
VxVM vxio WARNING V-5-0-164 Failed to join cluster name, aborting